Quantification of tau in cerebrospinal fluid by immunoaffinity enrichment and tandem mass spectrometry.

نویسندگان

  • Thomas McAvoy
  • Michael E Lassman
  • Daniel S Spellman
  • Zhenlian Ke
  • Bonnie J Howell
  • Oitak Wong
  • Lan Zhu
  • Michael Tanen
  • Arie Struyk
  • Omar F Laterza
چکیده

BACKGROUND Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically sensitive and selective immunoaffinity liquid chromatography-tandem mass spectrometry (LC-MS/MS) (IA-MS) assay. METHODS IA-MS sample analysis involved the addition of an internal standard, immunoaffinity purification of tau using a tau monoclonal antibody coupled to magnetic beads, trypsin digestion, and quantification of a surrogate tau peptide by LC-MS/MS using a Waters Trizaic nanoTile ultraperformance LC microfluidic device. Further characterization of tau peptides was performed by full-scan MS using a Thermo Orbitrap LC-MS. CSF samples from a cohort of age-matched controls and patients with AD were analyzed by the IA-MS method as well as a commercially available immunoassay. RESULTS The IA-MS assay had intra- and interassay imprecision values of 3.2% to 8.1% CV and 7.8% to 18.9% C, respectively, a mean recovery of 106%, and a limit of quantification of 0.25 pmol/L and was able to quantify tau concentrations in all human specimens tested. The IA-MS assay showed a correlation of R(2) = 0.950 against a total-tau immunoassay. In patients with AD, tau was increased approximately 2-fold. CONCLUSIONS Combining immunoaffinity enrichment with microflow LC-MS/MS analysis is an effective approach for the development of a highly selective assay to measure total tau and, potentially, other posttranslationally modified forms of tau in CSF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of thyroglobulin, a low-abundance serum protein, by immunoaffinity peptide enrichment and tandem mass spectrometry.

BACKGROUND Quantification of serum tumor markers plays an important role in determining whether patients treated for cancer require further therapy. Whereas large-scale proteomic efforts aim to identify novel tumor markers to facilitate early detection, optimization of methods for quantifying known tumor markers offers another approach to improving management of malignancies. For example, immun...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Validation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column

This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 2014