Central Corneal Thickness and Corneal Endothelial Cell Changes Caused by Contact Lens Use in Diabetic Patients
نویسندگان
چکیده
PURPOSE To analyze the effects of soft contact lenses on central corneal thickness and morphologic characteristics of the corneal endothelium in diabetic patients. MATERIALS AND METHODS Ultrasound pachymetry and noncontact specular microscopy were performed on 26 diabetic patients who regularly use soft contact lenses (group 1), 27 diabetic patients who do not use soft contact lenses (group 2) and 30 normal subjects (group 3). We compared the values in each group using the Mann-Whitney test. RESULTS The central cornea was found to be thicker in diabetic patients, both those who use and do not use contact lenses, than in the normal control group. The central corneal thickness was significantly higher in group 1 (564.73 ± 35.41 μm) and group 2 (555.76 ± 45.96 μm) than in the control group (534.05 ± 27.02 μm), but there was no statistically significant difference between groups 1 and 2. Endothelial cell density was significantly different between the groups, and was smallest in the group of diabetic patients using contact lenses. The coefficient of variation of cell size was significantly higher and the percentage of hexagonal cells was significantly lower in contact lens using diabetic patients than in non-contact lens using diabetic patients and in the control group. CONCLUSION Central corneal thickness and endothelial cell density is more affected by diabetes mellitus, and corneal endothelial cell morphology is more affected by contact lens use, when compared with normal subjects.
منابع مشابه
Corneal hydration control in normal and alloxan-induced diabetic rabbits.
Reports of increased corneal thickness and altered endothelial morphology suggest that there is abnormal corneal hydration control in diabetic patients. To study the possible influence of hyperglycemia on corneal hydration control, experiments were done on normal and alloxan-induced diabetic rabbits to assess: (1) stromal dry weight, hydration, and swelling pressure; (2) corneal thickness and c...
متن کاملCorneal hydration control in diabetes mellitus.
PURPOSE To assess the effects of diabetes mellitus on corneal structure and function. METHODS The authors measured endothelial permeability to fluorescein and corneal deswelling for 7.5 hours after 2 hours of hypoxic contact lens wear in 20 patients with diabetes who had nonproliferative retinopathy and 21 age-matched control subjects. Central corneal endothelial photographs were also taken. ...
متن کاملEffects of diabetic keratopathy on corneal optical density, central corneal thickness, and corneal endothelial cell counts
Diabetic keratopathy is an ocular complication that occurs with diabetes. In the present study, the effect of diabetic keratopathy on corneal optical density, central corneal thickness, and corneal endothelial cell count was investigated. One hundred and eighty diabetic patients (360 eyes) were enrolled in the study during the period from March, 2012 to March, 2013. The patients were divided in...
متن کاملCorneal Endothelial Changes in Patients of Type 2 Diabetes Mellitus Using Specular Microscopy
Objectives: To compare corneal endothelial cell changes namely, endothelial cell density (ECD), percentage polymegathism (CV) and pleomorphism (6A) along with central corneal thickness (CCT) in patients of type 2 diabetes mellitus with normal age and sexmatched subjects. To correlate corneal endothelial changes with diabetic retinopathy status, total duration of disease and glycemic control (Hb...
متن کاملCentral Corneal Thickness, Corneal Endothelial Cell Density, and Lens Capsule Thickness in Normotensive Patients with and without Pseudoexfoliation Syndrome
Purpose: To compare central corneal thickness (CCT), corneal endothelial cell density, and lens capsule thickness in normotensive patients with and without pseudoexfoliation syndrome (PXS) Methods: This was a prospective, comparative, descriptive study. Normotensive candidates for cataract surgery with (study group) and without (control group) PXS were enrolled in the study. CCT and corneal end...
متن کامل