Bone structure after removal of internal fixation plates.

نویسندگان

  • J W Rosson
  • G W Petley
  • J R Shearer
چکیده

We used single-photon absorptiometry to assess the forearm bones after the removal of internal fixation plates in 14 patients. We found convincing evidence of cortical atrophy in only one patient, in whom the plates had been removed prematurely after only 16 months. It is suggested that such plates should be retained for at least 21 months, to allow bone density to return to its prefracture level. The recommendations of the AO/ASIF group are supported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of metal plates on post-traumatic remodelling and bone mass.

The long-term effect of stainless steel and titanium alloy plates on structural remodelling and bone mass of osteotomised canine femora was studied and the effects of early and late removal of plates were compared in 27 adult Beagles. Radiological, histological, histomorphometric and tetracycline fluorescence studies led to three conclusions. First, the continuous (60 weeks) presence of plates,...

متن کامل

The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs.

An experimental study is reported of fracture healing in the femora of 36 Beagle dogs, comparing the results of using stainless steel plates with those of using less rigid titanium alloy plates. The alloy plates led to the appearance of a small amount of periosteal callus without any histological evidence of fracture instability, thus allowing the radiological assessment of fracture union. This...

متن کامل

Hardware Removal Due to Infection after Open Reduction and Internal Fixation: Trends and Predictors

Background:  Little is known about trends and predictors of hardware related infection following open reduction and internal fixation (ORIF) of extremity fractures, one of the major causes of failure following ORIF. The present study was designed and conducted to determine trends and predictors of infection-related hardware removal following ORIF of extremities using a nationally representative...

متن کامل

Heterotopic Ossification around the Knee after Internal Fixation of a Complex Tibial Plateau Fracture Combined with the Use of Demineralized Bone Matrix (DBM): A Case Report

Demineralized bone matrix has been successfully commercialized as an alternative bone graft material that not only can function as filler but also as an osteoinductive graft. Numerous studies have confirmed its beneficial use in clinical practice. Heterotopic ossification after internal fixation combined with the use of demineralized bone matrix has not been widely reported. In this paper we de...

متن کامل

Elective implant removal in symptomatic patients after internal fixation of proximal humerus fractures improves clinical outcome

BACKGROUND Operative treatment is the standard for severely displaced proximal humerus fractures, but functional impairment can persist. Retaining of the implant can be a reason and in other fracture situations has proved to ameliorate patient satisfaction. The aim of this study was to analyse the functional outcome after locking plate removal in proximal humerus fractures. METHODS In a two-y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 1991