Energy Efficiency of Refrigeration Systems for High - Heat - Flux Microelectronics

نویسندگان

  • P. E. Phelan
  • Y. Gupta
  • H. Tyagi
  • R. S. Prasher
  • J. Catano
  • G. Michna
  • R. Zhou
  • J. Wen
  • M. Jensen
  • Y. Peles
چکیده

Increasingly, military and civilian applications of electronics require extremely high-heat fluxes on the order of 1000 W /cm2. Thermal management solutions for these severe operating conditions are subject to a number of constraints, including energy consumption, controllability, and the volume or size of the package. Calculations indicate that the only possible approach to meeting this heat flux condition, while maintaining the chip temperature below 65°C, is to utilize refrigeration. Here, we report an initial thermodynamic optimization of the refrigeration system design. In order to hold the outlet quality of the fluid leaving the evaporator to less than approximately 20%, in order to avoid reaching critical heat flux, the refrigeration system design is dramatically different from typical configurations for household applications. In short, a simple vapor-compression cycle will require excessive energy consumption, largely because of the additional heat required to return the refrigerant to its vapor state before the compressor inlet. A better design is determined to be a “two-loop” cycle, in which the vapor-compression loop is coupled thermally to a pumped loop that directly cools the high-heat-flux chip. DOI: 10.1115/1.4003041

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Refrigeration Systems for High-heat-flux Microelectronics

1 Corresponding author: Telephone (480)965-1625, email [email protected] 2 Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic University ABSTRACT Increasingly, military and civilian applications of electronics require extremely high heat fluxes, on the order of 1000 W/cm. Thermal management solutions for these severe operating conditions are subject to a number of ...

متن کامل

Exergoeconomic Evaluation of LNG and NGL Co-production Process Based on the MFC Refrigeration Systems

In this paper, exergy and exergoeconomic analysis is performed on the recently proposed process forthe coproduction of liquefied natural gas (LNG) and natural gas liquids (NGL) based on the mixedfluid cascade (MFC) refrigeration systems, as one of the most important and popular natural gasliquefaction processes. To carry out this analysis, at first, the proposed process is sim...

متن کامل

Superstructure of Cogeneration of Power, Heating, Cooling and Liquid Fuels Using Gasification of Feedstock with Primary Material of Coal for Employing in LNG Process

Using absorption refrigeration cycles instead of vapor compression refrigeration cycles can drastically decrease energy consumption. In these systems, high level of energy consumption is reduced due to the partially elimination of vapor compression refrigeration systems. On the other hand, utilization of waste heat of the plant, which is a very good opportunity for energy saving,  is possible. ...

متن کامل

Saving Energy by Exergetic Analysis of MTP Process Refrigeration System

The exergetic analysis is a tool that has been used successfully in many studies aiming a more rational energy consumption to reduce the cost of processes. With this analysis, it is possible to perform an evaluation of the overall process, locating and quantifying the degradation of exergy. This paper applies exergy approach for analyzing the heat exchanger network design and refrigeration of M...

متن کامل

Transient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation

Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010