Therapeutic analysis of Intrabeam‐based intraoperative radiation therapy in the treatment of unicentric breast cancer lesions utilizing a spherical target volume model
نویسندگان
چکیده
It is postulated that the outcomes in treating breast cancer with intraoperative radiotherapy (IORT) would be affected by the residual cancer cell distribution within the tumor bed. The three-dimensional (3D) radiation doses of IntrabeamTM (IB) IORT with a 4-cm spherical applicator at the energy of 50 and 40 kV were calculated. The modified linear quadratic model (MLQ) was used to estimate the radiobiological responses of the cancer cells and interspersed normal tissues with various radiosensitivities. By comparing the average survival fraction of normal tissues in IB-IORT and uniform dose treatment for the same level of cancer cell killing, the therapeutic ratios (TRs) were derived. The equivalent uniform dose (EUD) was found to increase with the prescription dose and decrease with the cancer cell infiltrating distance. For 50 kV beam at the 20 Gy prescription dose, the EUDs are 18.03, 16.49 and 13.56, 11. 29, and 9.28 Gy respectively, for 1.5, 3.0, 6.0, 9, and 15.0 mm of the cancer cell infiltrating distance into surrounding tissue. The dose rate of 50 kV is at least 1.87× higher than that of 40 kV beam. The EUDs of 50 kV beam are up to 15% higher than that of the 40 kV beam. The TR increases with the prescription dose, but decreases with the distance of cancer cell infiltration distance. Average TRs of 50 kV beam are up to 30% larger than that of 40 kV beam. In conclusion, IB-IORT can provide a possible therapeutic advantage on sparing more normal tissue compared with the External Beam IORT (EB-IORT) for shallowly populated unicentric breast lesion. Our data suggest that IB-IORT dose size should be adjusted based on the individual patient's cancer cell infiltrating distance for delivering an effective dose, one dose-fits-all regimen may have undertreated some patients with large cancer infiltrating distance.
منابع مشابه
Dosimetric pitfalls in the application of shielding disk in breast intraoperative electron radiation therapy
Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...
متن کاملStereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters
Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...
متن کاملIntraoperative radiotherapy (IORT) for breast cancer using the Intrabeam system.
INTRODUCTION Intraoperative radiotherapy (IORT) with low-energy X-rays (30-50 KV) is an innovative technique that can be used both for accelerated partial breast irradiation (APBI) and intraoperative boosting in patients affected by breast cancer. Immediately after tumor resection the tumor bed can be treated with low-distance X-rays by a single high dose. Whereas often a geographic miss in cov...
متن کاملOptimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy
Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کامل