Parameter Identification of Pressure Sensors by Static and Dynamic Measurements
نویسندگان
چکیده
Fast identification methods of pressure sensors are investigated. With regard to a complete accurate sensor parameter identification two different measurement methods are combined. The approach consists on one hand in performing static measurements – an applied pressure results in a membrane deformation measured interferometrically and the corresponding output voltage. On the other hand optical measurements of the modal responses of the sensor membranes are performed. This information is used in an inverse identification algorithm to identify geometrical and material parameters based on a FE model. The number of parameters to be identified is thereby generally limited only by the number of measurable modal frequencies. A quantitative evaluation of the identification results permits furthermore the classification of processing errors like etching errors. Algorithms and identification results for membrane thickness, intrinsic stress and output voltage will be discussed in this contribution on the basis of the parameter identification of relative pressure sensors.
منابع مشابه
Stresa, Italy, 25-27 April 2007 PARAMETER IDENTIFICATION OF PRESSURE SENSORS BY STATIC AND DYNAMIC MEASUREMENTS
Fast identification methods of pressure sensors are investigated. With regard to a complete accurate sensor parameter identification two different measurement methods are combined. The approach consists on one hand in performing static measurements – an applied pressure results in a membrane deformation measured interferometrically and the corresponding output voltage. On the other hand optical...
متن کاملWeight Measurements by Using Simple Optical-Fiber Sensors (RESEARCH NOTE)
The use of different optical-fiber sensors for weighing measurements is Abstract described. By using three different mechanical stressing mechanisms, the operation of the fiber-to-fiber transducer systems are tested and the results are presented. Parameters such as sensitivity, hysteresis, resolution, and dynamic range are measured. A comparison of the results has shown that the sensor system m...
متن کاملبررسی بیماری ACL با استفاده از ابزار سنجش توزیع فشار کف پا به صورت بیسیم
Received: 14 Apr, 2013 Accepted: 13 Jun, 2013Abstract Background & Aims: One of the methods for abnormalities motion is the gait analysis using the analysis of plantar pressure distribution. This method is not only very costly but also it needs the adequate space to locate the equipment in some cases connection of the accessories to the patient leads to the limitation of the patient’s motions....
متن کاملA Fully Integrated Method for Dynamic Rock Type Characterization Development in One of Iranian Off-Shore Oil Reservoir
Rock selection in modeling and simulation studies is usually based on two techniques; routinely defined rock types and those defined by special core analysis (SCAL). The challenge in utilizing these two techniques is that they are frequently assumed to be the same, but in practice, static rock-types (routinely defined) are not always representative of dynamic rock-types (SCAL defined) in the re...
متن کاملSimultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings
BACKGROUND We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/0802.3055 شماره
صفحات -
تاریخ انتشار 2007