New Dynamic Plate System Combined with Titanium Mesh Cage and Bone Graft in the Treatment of Cervical Spondylosis.

نویسندگان

  • Wenjie Wu
  • Yunbei Yang
  • Hao Liu
  • Yin Hong
  • Quan Gong
  • Tao Li
  • Limin Liu
  • Yueming Song
چکیده

AIM Dynamic plates have been popularized to promote cervical spine fusion. There are no studies comparing the effectiveness and complications between traditional static plates and new dynamic plates (Vectra-T, Synthes, Switzerland). MATERIAL AND METHODS From June 2009 to October 2012, 70 patients underwent anterior cervical corpectomy and fusion (ACCF) in our hospital for the treatment of cervical spondylosis. Vectra-T plate was used in 36 patients (dynamic group) while traditional static plate was used in 34 patients (static group). Sagittal section angle, sagittal plane mobility, coronal angle of the titanium mesh cage were measured and the change of sedimentation rate was calculated at the postoperative 3 < sup > rd < /sup > , 6 < sup > th < /sup > , 12 < sup > th < /sup > months and at the end of follow-up period for each patient. The Japanese Orthopedic Association (JOA) score and local cervical angle were also measured before, immediately after surgery and at the end of follow-up period. These data were compared for both groups. RESULTS The follow-up period was between 12 and 38 months. The clinical outcome was similar in both groups based on the JOA score, local cervical angle and regional cervical angle. All patients had good clinical outcome without fracture of the plates or screws. There were no differences between the two groups at the 3rd, 6th and 12th months after surgery regarding to fusion rate (p > 0.05). Settling of the construct and plate migration was similar between the groups at all time points. CONCLUSION There was no statistically significant difference between dynamic plates and static plates regarding to fusion rate. The clinical outcomes and radiographic changes were also similar in both groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Results to 4-year follow-up of the treatment of the cervical stenosis by corpectomy, titanium mesh cage and anterior plate fixation].

BACKGROUND Cervical spondylotic myelopathy is caused by cervical stenosis. Several techniques have been described for the treatment of multilevel disease, such as the anterior corpectomy with titanium mesh cage and anterior cervical plate placement, which has the advantage of performing a wider decompression and using the same bone as graft. However, it has caused controversy since the collapse...

متن کامل

Biomechanical Evaluation of Anterior Cervical Spine Fixation Devices

The anterior cervical plate fixation systems have been widely used in treatment of complex spinal disorders such as traumatic lesion, disc hernination, tumor, spondylosis, arthritides, and others. Combined with bone graft or other fusion techniques the satisfactory outcomes were higher than 88% (Clements 1990, Naito 1993,Bose 1998, Schneeberger 1999). Among the screw plate fixation systems, Cas...

متن کامل

The new Zero-P implant can effectively reduce the risk of postoperative dysphagia and complications compared with the traditional anterior cage and plate: a systematic review and meta-analysis

BACKGROUND The low-profile angle-stable spacer Zero-P is a new kind of cervical fusion system that is claimed to limit the potential drawbacks and complications. The purpose of this meta-analysis was to compare the clinical and radiological results of the new Zero-P implant with those of the traditional anterior cage and plate in the treatment of symptomatic cervical spondylosis, and provides c...

متن کامل

Anterior decompression and internal fixation for lower cervical spine dislocation

Objective: To summarize neurological outcome and complications after skull distraction combination of anterior cervical surgery managed with corpectomy, titanium mesh cage reconstruction, and cervical locking plate. Methods: A total of 42 patients with lower cervical spine fracture and dislocation were included in this study between May 2009 and September 2014. The average follow-up time was 18...

متن کامل

Anterior cervical reconstruction using titanium mesh cages.

BACKGROUND Surgical management of cervical lesions with reconstruction procedures has remarkably expanded the options available in the last decade. Anterior cervical corpectomy with titanium mesh reconstruction is one of the effective method of cervical spine reconstruction. METHODS We studied 17 consecutive cases in whom corpectomy and decompression was performed. Fusion with titanium mesh c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2016