Malposition of the right ventricular lead into the left ventricle is an unusual complication of challenging management. We report a case of an elderly woman with a dual chamber permanent pacemaker implanted 2 months before admission because of high grade AV block, who presented to our institution with sub acute subdural hematoma along the left fronto-parietal area. Incidental ventricular pacemaker lead in the left ventricle was found on chest CT scan. The patient was not candidate for anticoagulation due to her recent subdural hematoma, hence a discussion about the risks of explantation of the pacemaker lead led to patient's lead extraction without any complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of a malpositioned transcutaneous ventricular pacing lead in the left ventricle via direct aortic puncture.

An 81-year-old woman with progressive cough was hospitalized 2 weeks following transcutaneous pacemaker implantation. Imaging revealed an absent brachiocephalic vein and aberrant course of a ventricular lead into the aorta with implantation into the left ventricle. We describe the unusual anatomic course, diagnosis, and surgical extraction of a malpositioned pacer lead.

متن کامل

A misleading distal anterior cerebral artery aneurysm

BACKGROUND Aneurysmal rupture causing pure acute subdural hematoma (aSDH) is rare. In the four previously reported cases of distal anterior cerebral artery (ACA) aneurysm resulting in pure aSDH, blood distribution in the interhemispheric (IH) space has systematically incriminated the distal ACA as the source of rupture. We present a misleading case of a distal ACA rupture resulting in convexity...

متن کامل

Right bundle branch block pattern during right ventricular permanent pacing: Is it safe or not?

The present case report describes a patient with dual chamber pacemaker whose surface ECG demonstrated paced right bundle branch block pattern suggesting a malpositioned ventricular lead in the left ventricle. However, diagnostic work-up revealed that the lead was appropriately located in the right ventricular apex. Diagnostic maneuvers and clues for differentiating safe right bundle branch blo...

متن کامل

Inadvertent malposition of a permanent pacemaker ventricular lead into the left ventricle which was initially missed and diagnosed two years later: a case report

INTRODUCTION Inadvertent malposition of a pacemaker ventricular lead into the left ventricle is an uncommon event, and its actual incidence is probably unknown. It may be underestimated and underreported because of a possible asymptomatic course. A 12-lead electrocardiogram is important to confirm proper placement. CASE PRESENTATION We report a case of a 60-year-old Caucasian man with a malpo...

متن کامل

Refractory Spontaneous Chronic Subdural Hematoma: A Rare Presentation of an Intracranial Arteriovenous Fistula

The author has encountered a 67-year-old man with dural arteriovenous fistula (AVF) presenting as a non-traumatic chronic subdural hematoma (CSDH). This previously healthy patient was hospitalized due to progressive headache with subacute onset. He underwent burr-hole surgery twice for evacuating the left CSDH that was thickest at the posterior temporal area. The operative procedure and finding...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012