Numerical simulations of radon as an in situ partitioning tracer for quantifying NAPL contamination using push-pull tests.

نویسندگان

  • B M Davis
  • J D Istok
  • L Semprini
چکیده

Presented here is a reanalysis of results previously presented by [Davis, B.M., Istok, J.D., Semprini, L., 2002. Push-pull partitioning tracer tests using radon-222 to quantify non-aqueous phase liquid contamination. J. Contam. Hydrol. 58, 129-146] of push-pull tests using radon as a naturally occurring partitioning tracer for evaluating NAPL contamination. In a push-pull test where radon-free water and bromide are injected, the presence of NAPL is manifested in greater dispersion of the radon breakthrough curve (BTC) relative to the bromide BTC during the extraction phase as a result of radon partitioning into the NAPL. Laboratory push-pull tests in a dense or DNAPL-contaminated physical aquifer model (PAM) indicated that the previously used modeling approach resulted in an overestimation of the DNAPL (trichloroethene) saturation (S(n)). The numerical simulations presented here investigated the influence of (1) initial radon concentrations, which vary as a function of S(n), and (2) heterogeneity in S(n) distribution within the radius of influence of the push-pull test. The simulations showed that these factors influence radon BTCs and resulting estimates of S(n). A revised method of interpreting radon BTCs is presented here, which takes into account initial radon concentrations and uses non-normalized radon BTCs. This revised method produces greater radon BTC sensitivity at small values of S(n) and was used to re-analyze the results from the PAM push-pull tests reported by Davis et al. The re-analysis resulted in a more accurate estimate of S(n) (1.8%) compared with the previously estimated value (7.4%). The revised method was then applied to results from a push-pull test conducted in a light or LNAPL-contaminated aquifer at a field site, resulting in a more accurate estimate of S(n) (4.1%) compared with a previously estimated value (13.6%). The revised method improves upon the efficacy of the radon push-pull test to estimate NAPL saturations. A limitation of the revised method is that 'background' radon concentrations from a non-contaminated well in the NAPL-contaminated aquifer are needed to accurately estimate NAPL saturation. The method has potential as a means of monitoring the progress of NAPL remediation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

470-481 Gw J-a 03

The release of nonaqueous phase liquids (NAPLs) to the subsurface environment can create long-term sources of ground water contamination as the NAPL slowly dissolves into ground water (Mercer and Cohen 1990; Cohen and Mercer 1993). Effective remediation of subsurface NAPL contamination requires that NAPL be accurately located and saturations quantified. This is particularly important for dense ...

متن کامل

Push-pull partitioning tracer tests using radon-222 to quantify non-aqueous phase liquid contamination.

Naturally occurring radon in groundwater can be used as an in situ partitioning tracer for locating and quantifying non-aqueous phase liquid (NAPL) contamination in the subsurface. When combined with the single-well, push-pull test, this methodology has the potential to provide a low-cost alternative to inter-well partitioning tracer tests. During a push-pull test, a known volume of test soluti...

متن کامل

Static and push-pull methods using radon-222 to characterize dense nonaqueous phase liquid saturations.

Naturally occurring radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and noncontaminated portions of an aquifer, while the push-pull method involves the injection (push) and extraction (pull) of a rad...

متن کامل

Single-well "push-pull" partitioning tracer test for NAPL detection in the subsurface.

Previous environmental applications of partitioning tracer tests to detect and quantify nonaqueous phase liquid (NAPL) contamination in the subsurface have been limited to well-to-well tests. However, theory and numerical modeling suggests that single-well injection-extraction ("push-pull") partitioning tracer tests can also potentially detect and quantify NAPL contamination. In this type of te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of contaminant hydrology

دوره 78 1-2  شماره 

صفحات  -

تاریخ انتشار 2005