Multi-slice perfusion-based functional MRI using the FAIR technique: comparison of CBF and BOLD effects.

نویسندگان

  • S G Kim
  • N V Tsekos
  • J Ashe
چکیده

Perfusion-weighted imaging techniques employing blood water protons as an endogenous tracer have poor temporal resolution because each image should be acquired with an adequate spin 'tagging' time. Thus, perfusion-based functional magnetic resonance imaging studies are typically performed on a single slice. To alleviate this problem, a multi-slice flow-sensitive alternating inversion recovery technique has been developed. Following a single inversion pulse and a delay time, multi-slice echo-planar images are acquired sequentially without any additional inter-image delay. Thus, the temporal resolution of multi-slice FAIR is almost identical to that of single slice techniques. The theoretical background for multi-slice FAIR is described in detail. The multi-slice FAIR technique has been successfully applied to obtain three-slice cerebral blood flow based functional images during motor tasks. The relative CBF change in the contralateral motor/sensory area during unilateral thumb-digit opposition is 45.0+/-12.2% (n=9), while the blood oxygenation level dependent signal change is 1.5+/-0.4 SD%. Relative changes of the oxygen consumption rate can be estimated from CBF and BOLD changes using FAIR. The BOLD signal change is not correlated with the relative CBF increase, and thus caution should be exercised when interpreting the BOLD change as a quantitative index of the CBF change, especially in inter-subject comparisons.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI

Typical simultaneous blood oxygenation-level dependent (BOLD) and arterial spin labeling (ASL) sequences acquire two echoes, one perfusion-sensitive and one BOLD-sensitive. However, for ASL, spatial resolution and brain coverage are limited due to the T1 decay of the labeled blood. This study applies a sequence combining a multiband acquisition with four echoes for simultaneous BOLD and pseudo-...

متن کامل

Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity

A novel sequence has been introduced that combines multiband imaging with a multi-echo acquisition for simultaneous high spatial resolution pseudo-continuous arterial spin labeling (ASL) and blood-oxygenation-level dependent (BOLD) echo-planar imaging (MBME ASL/BOLD). Resting-state connectivity in healthy adult subjects was assessed using this sequence. Four echoes were acquired with a multiban...

متن کامل

Towards quantification of blood-flow changes during cognitive task activation using perfusion-based fMRI.

Multi-slice perfusion-based functional magnetic resonance imaging (p-fMRI) is demonstrated with a color-word Stroop task as an established cognitive paradigm. Continuous arterial spin labeling (CASL) of the blood in the left common carotid artery was applied for all repetitions of the functional run in a quasi-continuous fashion, i.e., it was interrupted only during image acquisition. For compa...

متن کامل

Pii: S0730-725x(01)00436-2

Functional MRI (fMRI) studies designed for simultaneously measuring Blood Oxygenation Level Dependent (BOLD) and Cerebral Blood Flow (CBF) signal often employ the standard Flow Alternating Inversion Recovery (FAIR) technique. However, some sensitivity is lost in the BOLD data due to inherent T1 relaxation. We sought to minimize the preceding problem by employing a modified UN-inverted FAIR (UNF...

متن کامل

A CBF-based event-related brain activation paradigm: characterization of impulse-response function and comparison to BOLD.

A perfusion-based event-related functional MRI method for the study of brain activation is presented. In this method, cerebral blood flow (CBF) was measured using a recently developed multislice arterial spin-labeling (ASL) perfusion imaging method with rapid spiral scanning. Temporal resolution of the perfusion measurement was substantially improved by employing intertrial subtraction and stim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NMR in biomedicine

دوره 10 4-5  شماره 

صفحات  -

تاریخ انتشار 1997