A protein-based electrochemical biosensor for detection of tau protein, a neurodegenerative disease biomarker.
نویسندگان
چکیده
A protein-based electrochemical biosensor was developed for detection of tau protein aimed towards electrochemically sensing misfolding proteins. The electrochemical assay monitors tau-tau binding and misfolding during the early stage of tau oligomerization. Electrochemical impedance spectroscopy was used to detect the binding event between solution tau protein and immobilized tau protein (tau-Au), acting as a recognition element. The charge transfer resistance (Rct) of tau-Au was 2.9 ± 0.6 kΩ. Subsequent tau binding to tau-Au decreased the Rct to 0.3 ± 0.1 kΩ (90 ± 3% decrease) upon formation of a tau-tau-Au interface. A linear relationship between the Rct and the solution tau concentration was observed from 0.2 to 1.0 μM. The Rct decrease was attributed to an enhanced charge permeability of the tau-tau-Au surface to a redox probe [Fe(CN)6](3-/4-). The electrochemical and surface characterization data suggested conformational and electrostatic changes induced by tau-tau binding. The protein-based electrochemical platform was highly selective for tau protein over bovine serum albumin and allowed for a rapid sample analysis. The protein-based interface was selective for a non-phosphorylated tau441 isoform over the paired-helical filaments of tau, which were composed of phosphorylated and truncated tau isoforms. The electrochemical approach may find application in screening of the early onset of neurodegeneration and aggregation inhibitors.
منابع مشابه
An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...
متن کاملAu nanoparticles/g-C3N4 modified biosensor for electrochemical detection of gastric cancer miRNA based on hairpin locked nucleic acids probe
Objective: The annual incidence of cancer in the world is growing rapidly. The most important factor in the cure of cancers is their early diagnosis. miRNA, as a biomarker for early detection of cancer, has attracted a lot of attention. Methods: In this study, an electrochemical biosensor was developed to detect the amount of miR-106a, the biomarker of gastric cancer, by modifying a glass...
متن کاملP 97: Neurodegeneration Induced by Tau protein
Tau is one of several types of microtubule-associated proteins (MAPs), responsible for the assembly and stability of microtubule networks that is present only in neurons and predominantly localized in axons which its functions are tightly regulated by phosphorylation. Via as yet unknown mechanisms, tau becomes hyperphosphorylated and accompanies with neuronal degeneration, loss of synapses...
متن کاملInhibitory effect of corcin on aggregation of 1N/4R human tau protein in vitro
Objective(s):Alzheimer's disease (AD) is the most common age-related neurodegenerative disorder. One of the hallmarks of AD is an abnormal accumulation of fibril forms of tau protein which is known as a microtubule associated protein. In this regard, inhibition of tau aggregation has been documented to be a potent therapeutic approach in AD and tauopathies. Unfortunately, the available syntheti...
متن کاملA Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
A single-use, in vitro biosensor for the detection of T-Tau protein in phosphate-buffer saline (PBS) and undiluted human serum was designed, manufactured, and tested. Differential pulse voltammetry (DPV) served as the transduction mechanism. This biosensor consisted of three electrodes: working, counter, and reference electrodes fabricated on a PET sheet. Both working and counter electrodes wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 139 11 شماره
صفحات -
تاریخ انتشار 2014