Small Stem Total Hip Arthroplasty in Hypoplasia of the Femur
نویسندگان
چکیده
UNLABELLED Total hip arthroplasty in hypoplastic femurs is technically difficult and the incidence of complications and aseptic loosening is relatively high. Cemented, uncemented, off-the-shelf, and custom-made stems all have been advocated in these cases. From 1978 to 1997, we performed 86 total hip arthroplasties in 77 patients with a hypoplastic femur using a cemented, off-the-shelf, small, curved, cobalt-chromium stem. We hypothesized results equaled those of the identical but larger-sized stems in normal-sized femora which were used as comparisons. Clinical and radiographic evaluations were performed. Minimum followup was 4.2 years (mean, 12 years; range, 4.2-20.3 years); mean Harris hip score was 88, and mean hip flexion was 104 degrees . Six stems were revised: four because of aseptic loosening, one after a femoral fracture, and one because of malpositioning. Complications included one perforation and one fracture of the femur, one fracture, one nonunion of the greater trochanter, and one deep infection. Implant survivorship for all hips at 15 years with aseptic revision of the stem as the end point was 90% (confidence interval, 82-99) which equaled results of the larger stems. The small off-the-shelf cemented Weber stem has a high long-term survival and a low complication rate. Survival compares favorably with other small-sized total hip systems. LEVEL OF EVIDENCE Level III, therapeutic study, case-control.
منابع مشابه
Bone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملFinite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کامل