Thoracic size-selective sampling of fibres: performance of four types of thoracic sampler in laboratory tests.

نویسندگان

  • A D Jones
  • R J Aitken
  • J F Fabriès
  • E Kauffer
  • G Liden
  • A Maynard
  • G Riediger
  • W Sahle
چکیده

The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 microm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 microm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for d(ae) < 7 microm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM thoracic sampler tended to undersample the fibres relative to the thoracic convention. With the data divided into four classes based on fibre length, the size-selection characteristics appeared to be unaffected by fibre length for GK2.69, Modified SIMPEDS and CATHIA. Only the IOM thoracic sampler (with the foam selector) showed slightly lower selection for longer length classes of fibres. These results indicate that the tested samplers follow the thoracic sampling convention for fibres, and may be used to improve the quality and reliability of samples that are taken when there is likely to be significant background dust.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0003-4878(99)00039-3

We measured inhalable, thoracic, and so-called ``total'' wood dust exposure in British Columbia lumber mill workers. Particle-size selective sampling was conducted using the GSP and Seven hole inhalable samplers, the PEM thoracic sampler and the 37-mm closed-face cassette ``total'' sampler. All measurements were full-shift personal samples, obtained from randomly selected workers. We obtained i...

متن کامل

Pii: S0003-4878(99)00042-3

Existing samplers for the collection of bioaerosols have been designed with the aim of maintaining biological stability of the collected material, and in general do not select particles in accordance with international conventions for aerosol sampling. Many have uncharacterised sampling eciencies and few are designed as personal samplers. If standard personal dust samplers are used for bioaero...

متن کامل

Parallel particle impactor – novel size-selective particle sampler for accurate fractioning of inhalable particles

Adverse health effects due to exposure to airborne particles are associated with particle deposition within the human respiratory tract. Particle size, shape, chemical composition, and the individual physiological characteristics of each person determine to what depth inhaled particles may penetrate and deposit within the respiratory tract. Various particle inertial classification devices are a...

متن کامل

A collaborative European study of personal inhalable aerosol sampler performance.

Following the adoption of new international sampling conventions for inhalable, thoracic and respirable aerosol fractions, a working group of Comité Européen de Normalisation (CEN) drafted a standard for the performance of workplace aerosol sampling instruments. The present study was set up to verify the experimental, statistical and mathematical procedures recommended in the draft performance ...

متن کامل

Field performance of the CATHIA-T sampler and two cyclones against the standard Cowled sampler for thoracic fiber concentrations.

The performance of two thoracic samplers, the GK2.69 cyclone and the CATHIA-T sampler, and the GK3.51 cyclone was investigated in the field against the standard cowled sampler (current NIOSH 7400 method) to determine the effect of thoracic sampling. The CATHIA-T sampler and the GK2.69 cyclone were operated at 7 and 1.6 l min(-1), respectively. The GK3.51 sampler is related to the GK2.69 cyclone...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 49 6  شماره 

صفحات  -

تاریخ انتشار 2005