Dose-volume parameters and clinical outcome of CT-guided free-hand high-dose-rate interstitial brachytherapy for cervical cancer

نویسندگان

  • Yi Wang
  • Wei-Jun Ye
  • Le-Hui Du
  • Ai-Ju Li
  • Yu-Feng Ren
  • Xin-Ping Cao
چکیده

Currently, image-based 3-dimentional (3D) planning brachytherapy allows for a better assessment of gross tumor volume (GTV) and the definition and delineation of target volume in cervix cancer. In this study, we investigated the feasibility of our novel computed tomography (CT)-guided free-hand high-dose-rate interstitial brachytherapy (HDRISBT) technique for cervical cancer by evaluating the dosimetry and preliminary clinical outcome of this approach. Dose-volume histogram (DVH) parameters were analyzed according to the Gynecological GEC-ESTRO Working Group recommendations for image-based 3D treatment in cervical cancer. Twenty cervical cancer patients who underwent CT-guided free-hand HDRISBT between March 2009 and June 2010 were studied. With a median of 5 (range, 4-7) implanted needles for each patient, the median dose of brachytherapy alone delivered to 90% of the target volume (D90) was 45 (range, 33-54) Gyα/β10 for high-risk clinical target volume (HR-CTV) and 30 (range, 20-36) Gyα/β10 for intermediate-risk clinical target volume (IR-CTV). The percentage of the CTV covered by the prescribed dose (V100) of HR-CTV with brachytherapy alone was 81.9%-99.2% (median, 96.7%). With an additional dose of external beam radiotherapy (EBRT), the median D90 was 94 (range, 83-104) Gyα/β10 for HR-CTV and 77 (range, 70-87) Gyα/β10 for IR-CTV; the median dose delivered to 100% of the target volume (D100) was 75 (range, 66-84) Gyα/β10 for HR-CTV and 65 (range, 57-73) Gyα/β10 for IR-CTV. The minimum dose to the most irradiated 2 cc volume (D2cc) was 73-96 (median, 83) Gyα/β3 for the bladder, 64-98 (median, 73) Gyα/β3 for the rectum, and 52-69 (median, 61) Gyα/β3 for the sigmoid colon. After a median follow-up of 15 months (range, 3-24 months), two patients experienced local failure, and 1 showed internal iliac nodal metastasis. Despite the relatively small number of needles used, CT-guided HDRISBT for cervical cancer showed favorable DVH parameters and clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Salvage interstitial brachytherapy based on computed tomography for recurrent cervical cancer after radical hysterectomy and adjuvant radiation therapy: case presentations and introduction of the technique

PURPOSE Locally recurring cervical cancer after surgery and adjuvant radiotherapy remains a major therapeutic challenge. This paper presents a new therapeutic technique for such patients: interstitial brachytherapy (BT) guided by real-time three-dimensional (3D) computed tomography (CT). MATERIAL AND METHODS Sixteen patients with recurrent cervical cancer after radical surgery and adjuvant ex...

متن کامل

Treatment planning for high dose rate brachytherapy of cervical cancer based on total dose constraints.

OBJECTIVE To compare the inverse planning optimization based on total dose constraints versus conventional treatment plan (point A planning method) for cervical carcinoma, and evaluate the benefit of CT-based image-guided brachytherapy. METHODS We prospectively analyzed data of 10 consecutive patients with cervical cancer treated with external beam radiotherapy to the whole pelvis (45 Gy in 2...

متن کامل

Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancer

PURPOSE The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT) combined with high-dose-rate (HDR) intracavitary brachytherapy (ICBT) to improve dose distribution in cervical cancer treatment. MATERIAL AND METHODS For 42 cervical cancer patients, magnetic resonance imaging (MRI) scans were acquired after completion of whole...

متن کامل

Evaluating variation of Hot Spot Location in order to radiobiological calculation of Organ at Risk in High-dose- rate Brachytherapy of Cervical Cancer

Introduction: Gynecological malignancies present challenges in determining an appropriate volumetric dose due to the highly variable physiologic activity of the surrounding tissue. Because of the high doses used in brachytherapy, surrounding structures have the potential to move around in the dose region and receive unknown amounts of radiation. Calculating hotspot region from ...

متن کامل

Dose–volume histogram parameters of high-dose-rate brachytherapy for Stage I–II cervical cancer (≤4cm) arising from a small-sized uterus treated with a point A dose-reduced plan

We investigated the rectal dose-sparing effect and tumor control of a point A dose-reduced plan in patients with Stage I-II cervical cancer (≤4 cm) arising from a small-sized uterus. Between October 2008 and August 2011, 19 patients with Stage I-II cervical cancer (≤4 cm) were treated with external beam radiotherapy (EBRT) for the pelvis and CT-guided brachytherapy. Seven patients were treated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -