Reproducibility in echocardiographic assessment of the left ventricular global and regional function, the HUNT study.

نویسندگان

  • Anders Thorstensen
  • Havard Dalen
  • Brage Høyem Amundsen
  • Svein Arne Aase
  • Asbjørn Stoylen
چکیده

AIMS The study aimed to compare the inter-observer reproducibility of new and traditional measurements of the left ventricular (LV) global and regional function. METHODS AND RESULTS Two experienced echocardiographers performed 20 complete echo/Doppler examinations and 50 analyses on ten healthy subjects. All recordings were analysed for systolic and diastolic conventional and deformation measurements by both echocardiographers. Inter-observer mean error (absolute difference divided by the mean) was 4% and lowest (P = 0.001) for systolic M-mode annulus excursion. Mean error for the regional deformation indices was significantly higher than for all the global measurements (all P < 0.001). Mean error for analyses of the same recording was 34% (P = 0.002) lower for global systolic indices and 44% (P < 0.001) lower for global diastolic indices than inter-observer mean error for analyses made in separate recordings. CONCLUSION Systolic M-mode annulus excursion showed better inter-observer reproducibility than other traditional and newer measurements of LV systolic and diastolic function. Repeated analyses of the same recordings underestimate the more clinically relevant inter-observer reproducibility by approximately 40% for most measurements of LV function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation

Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...

متن کامل

Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method

Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...

متن کامل

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images

Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2010