Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner.
نویسندگان
چکیده
Recently, attempts to develop new types of swallowing function analysis with 320-detector-row multislice CT (320-MDCT) have been reported. The present report addresses (1) patient exposure, (2) operator exposure, and (3) spatial dose distribution. For dose measurement, a human-body phantom in which 303 thermoluminescent dosimeter elements were inserted and a survey meter was used. The patient position was confirmed with a single-volume scan at a tube voltage of 120 kV, a tube current of 10 mA, a rotation speed of 0.35 s/rot., a slice thickness of 0.5 mm, coverage of 160 mm, a scan field of view of 240 mm, a small focal spot size, and a gantry tilt angle of 22° (volume CT dose index displayed on the console 0.8 mGy, dose-length product 12.1 mGy cm). The effective dose for the patient in swallowing CT (SCT) was 3.9 mSv. The conversion factor for obtaining the effective dose was 0.0066 mSv/mGy cm. The effective dose for the operator was 0.002 mSv. In the operator exposure measurement, the ambient dose equivalent H*(10), that would be produced by an expanded and aligned radiation field at a depth 10 mm in the International Commission on Radiation Units and Measurements sphere, was 0.012 mSv. In this report, the safety of SCT, which has become possible with the introduction of 320-MDCT, was evaluated by measurement of the exposure to the patient and operator.
منابع مشابه
Evaluation of Patient Dose and Operator Dose in Swallowing CT Studies Performed with a 320-Detector-Row Multislice CT Scanner Names:
*KURAに登録されているコンテンツの利用については,著作権法に規定されている私的使用や引用などの範囲内で行ってください。 *著作権法に規定されている私的使用や引用などの範囲を超える利用を行う場合には,著作権者の許諾を得てください。ただし,著作権者 から著作権等管理事業者(学術著作権協会,日本著作出版権管理システムなど)に権利委託されているコンテンツの利用手続については ,各著作権等管理事業者に確認してください。 Title Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner Author(s) Kobayashi, Masanao; Koshida, Kichiro; Suzuki, ...
متن کاملDosimetric evaluation of a 320 detector row CT scanner unit
BACKGROUND The technologic improvements in Multislice scanners include the increment in the X-ray beam width. Some new CT scanners are equipped with a 320 detector row which allows a longitudinal coverage of 160 mm and a total of 640 slices for a single rotation. When such parameters are used the length of the traditional pencil chamber (10 cm) is no more appropriate to measure the standard wei...
متن کاملDose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.
BACKGROUND AND PURPOSE Recently introduced 320-detector row CT enables whole brain perfusion imaging compared to a limited scanning area in 64-detector row CT. Our aim was to evaluate patient radiation exposure in comprehensive stroke imaging by using multidetector row CT consisting of standard CT of the head, CTA of cerebral and cervical vessels, and CTP. MATERIAL AND METHODS Organ doses wer...
متن کاملMeasurement of organ dose in abdomen-pelvis CT exam as a function of mA, KV and scanner type by Monte Carlo method .
Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...
متن کاملRadiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.
PURPOSE To determine radiation doses from coronary computed tomographic (CT) angiography performed by using a 320-detector row volume scanner and evaluate how the effective dose depends on scan mode and the calculation method used. MATERIALS AND METHODS Radiation doses from coronary CT angiography performed by using a volume scanner were determined by using metal-oxide-semiconductor field-eff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiological physics and technology
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2012