Force production during squats performed with a rotational resistance device under stable versus unstable conditions.

نویسندگان

  • Gerard Moras
  • Jairo Vázquez-Guerrero
چکیده

[Purpose] Force production during a squat action on a rotational resistance device (RRD) under stable and unstable conditions. [Subjects and Methods] Twenty-one healthy males were asked to perform six sets of six repetitions of squats on an RRD on either stable or unstable surfaces. The stable and unstable sets were performed on different days. Muscular outputs were obtained from a linear encoder and a strain gauge fixed to a vest. [Results] Overall, the results showed no significant differences for any of the dependent variables across exercise modes. Forcemean outputs were higher in the concentric phase than in the eccentric phase for each condition, but there were no differences in velocity, time or displacement. The forcepeak was similar in the eccentric and concentric phases of movement under both stable and unstable conditions. There were no significant differences in forcemean between sets per condition or between conditions. [Conclusion] These results suggest that performing squats with a RRD achieves similar forcemean and forcepeak under stable and unstable conditions. The forcepeak produced is also similar in concentric and eccentric phases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads

The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m, body mass 77.4 ± 7.9 kg) were assessed while squatting, performing one set of three repetitions...

متن کامل

Isometric squat force output and muscle activity in stable and unstable conditions.

The purpose of this study was to assess the effect of stable vs. unstable conditions on force output and muscle activity during an isometric squat. Nine men involved in recreational resistance training participated in the investigation by completing a single testing session. Within this session subjects performed isometric squats either while standing directly on the force plate (stable conditi...

متن کامل

Effects of visibility and types of the ground surface on the muscle activities of the vastus medialis oblique and vastus lateralis

[Purpose] The purpose of this study was to compare the effects of visibility and types of ground surface (stable and unstable) during the performance of squats on the muscle activities of the vastus medialis oblique (VMO) and vastus lateralis (VL). [Subjects and Methods] The subjects were 25 healthy adults in their 20s. They performed squats under four conditions: stable ground surface (SGS) wi...

متن کامل

Effect of absolute and relative loading on muscle activity during stable and unstable squatting.

PURPOSE The purpose of this investigation was to determine the effect of stable and unstable conditions on one repetition maximum strength and muscle activity during dynamic squatting using absolute and relative loading. METHODS Ten recreationally weight-trained males participated in this study (age = 24.1 +/- 2.0 y, height = 178.0 +/- 5.6 cm, body mass = 83.7 +/- 13.4 kg, 1RM/body mass = 1.5...

متن کامل

Canadian Society for Exercise Physiology position stand: The use of instability to train the core in athletic and nonathletic conditioning.

The use of instability devices and exercises to train the core musculature is an essential feature of many training centres and programs. It was the intent of this position stand to provide recommendations regarding the role of instability in resistance training programs designed to train the core musculature. The core is defined as the axial skeleton and all soft tissues with a proximal attach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of physical therapy science

دوره 27 11  شماره 

صفحات  -

تاریخ انتشار 2015