Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.
نویسندگان
چکیده
PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism who had uneventful cataract surgery and AcrySof T3 toric or AcrySof IQ spherical monofocal IOL implantation. Surgically induced astigmatism (SIA) was calculated for eyes with postoperative keratometry results. Postoperative refractive astigmatism between groups and subgroups was compared based on the orientation of preoperative corneal astigmatism. RESULTS Of the eyes, 185 had a toric IOL and 138 had a spherical IOL. The mean preoperative corneal astigmatism was 1.06 D, with no significant difference between IOL groups or by axis of astigmatism. The mean SIA was 0.25 D, with no significant difference between IOL groups. The mean postoperative refractive astigmatism was statistically significantly lower in the toric IOL group than in the spherical IOL group (0.31 D versus 1.06 D; P<.001). The axis of preoperative corneal astigmatism was not a significant factor in the toric IOL group. In the spherical IOL group, the residual astigmatism was slightly higher for with-the-rule than for against-the-rule astigmatism (1.07 D versus 0.70 D; P<.001). CONCLUSIONS The mean refractive astigmatism after cataract surgery in patients with 0.75 D to 1.38 D of corneal astigmatism was significantly lower when a toric IOL was implanted. Postoperative refractive astigmatism with the toric IOL was independent of preoperative corneal astigmatism axis orientation. FINANCIAL DISCLOSURE Neither author has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power.
OBJECTIVES To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. METHOD In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically ind...
متن کاملClinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator
PURPOSE To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs) using preoperative keratometry from an optical low coherence reflectometry (OLCR) ocular biometer (Lenstar® LS900) and the built-in Barrett toric calculator. PATIENTS AND METHODS A prospective observational study recruited one or both eyes of subjects who underwent uncomplica...
متن کاملAstigmatism correction with toric IOL: analysis of visual performance, position, and wavefront error.
PURPOSE To evaluate astigmatism correction, visual performance, intraocular lens (IOL) position, and wavefront error after implantation of toric IOLs in patients with cataract. METHODS This prospective study comprised 30 eyes of 30 patients with cataract who were candidates for phacoemulsification and implantation of the AcrySof toric IOL (Alcon Laboratories, Inc., Fort Worth, TX). Mean preop...
متن کاملCataract Surgery in Eyes with Low Corneal Astigmatism: Implantation of the Acrysof IQ Toric SN6AT2 Intraocular Lens
PURPOSE To assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients with low corneal astigmatism. METHODS This study is a retrospective, consecutive, single surgeon series of 98 eyes of 88 patients (with low preoperative corneal astigmatism) undergoin...
متن کاملAssessing the Likely Effect of Posterior Corneal Curvature on Toric IOL Calculation for IOLs of 2.50 D or Greater Cylinder Power.
PURPOSE To establish whether average refractive overcorrection or undercorrection of corneal astigmatism based on the orientation (rule) of the astigmatism occurs if toric intraocular lenses (IOLs) are calculated on the basis of anterior corneal measurements in eyes requiring toric IOL cylinder power of 2.50 diopters (D) or greater. METHODS One hundred thirteen consecutive eyes with anterior ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2011