چکیده
The aim of this study was to determine how an ultra-short anatomic uncemented stem vs a diaphyseal filling five-eighths porous coated uncemented femoral stem (conventional stem) affects the survival of primary total hip arthroplasties in octogenarians. The current study consisted of 52 patients (55 hips) in the ultra-short stem group (mean age, 85.5±5.3 years) and 61 patients (72 hips) in the diaphyseal (conventional) stem group (mean age, 84.1±4.8 years). The predominant diagnosis was osteoarthritis, followed by osteonecrosis of the femoral head, in both groups. Average follow-up was 6.1 years (range, 5-8 years) in the ultra-short stem group and 6.3 years (range, 5-9 years) in the conventional stem group. Pre- (41 vs 39 points) and postoperative (85 vs 86 points) Harris hip scores were similar between groups (P=.131 and .129, respectively). The incidence of thigh pain was 0% (0 of 52 patients) in the ultra-short stem group and 15% (9 of 61 patients) in the conventional stem group. The revision rate was 1.8% (1 hip) in the ultra-short stem group and 1.4% (1 hip) in the conventional stem group. Survivorship of the femoral stem was 98.2% in the ultra-short stem group at 6.1 years and 98.6% in the conventional stem group at 6.3 years. Ultra-short anatomic and diaphyseal filling uncemented stems obtained osseointegration in all hips. However, the prevalence of thigh pain and periprosthetic fracture were significantly higher in the patients with a conventional stem than in those with an ultra-short stem. [Orthopedics. 2018; 41(1):28-34.].
منابع مشابه
Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty
BACKGROUND AND PURPOSE We hypothesized that an ultra-short stem would load the proximal femur in a more physiological way and could therefore reduce the adaptive periprosthetic bone loss known as stress shielding. PATIENTS AND METHODS 51 patients with primary hip osteoarthritis were randomized to total hip arthroplasty (THA) with either an ultra-short stem or a conventional tapered stem. The ...
متن کاملCortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up
BACKGROUND Short stems have become more and more popular for cementless total hip arthroplasty in the past few years. While conventional, uncemented straight stems for primary total hip arthroplasty (THA) have shown high survival rates in the long term, it is not known whether uncemented short stems represent a reasonable alternative. As cortical hypertrophy has been reported for short stems, t...
متن کاملThe relative cost of cemented and uncemented total hip arthroplasties.
The use of uncemented femoral stems in primary total hip arthroplasty (THA) has been slow to develop in the UK because of the lack of encouraging published long-term follow-up data, the continued success of the cemented primary THA, and the perceived excessive relative cost of the uncemented THA. In this article, we argue that the total costs of 3 "proven" uncemented stems are comparable with c...
متن کاملThe short stem GHEs in total hip replacement – experience after 380 implantations
INTRODUCTION Standard straight stems have been recognized as a gold standard implant in the field of hip replacement surgery. However, lately uncemented bone-preserving short stems started to gain more and more popularity. This was reflected in the increasing variety of available models. Up till now, short and mid-term results are available. PATIENTS AND METHODS In 2002, the cementless short ...
متن کاملMetal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants
BACKGROUND There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants. METHODS This paper r...