Neutral Conductor Size Selection for Balanced and Harmonic Infested Electrical System

نویسندگان

  • Azharudin Mukhtaruddin
  • Syed Idris
  • Syed Hasan
  • Muzamir Isa
  • Muhammad Mokhzaini Azizan
  • Baharuddin Ismail
چکیده

Basically neutral currents are absent in a balanced 3-phase system. However, in the presence of harmonics, neutral currents are naturally flowing. These harmonic-rich currents have been known to negatively affect the current carrying capability or ampacity of the neutral conductor. The effect can be due to two factors. One is due to the magnitude of the harmonic neutral current itself and the other is due to the presence of high frequencies in the current. It has been shown that neutral current magnitude has a direct relationship with content of harmonics in the phase currents. High frequency currents, on the other hand, lead to derating of cable ampacity. This paper study the effect on sizing of neutral conductor due to both factors. The study was done based on several available methods using simulated data. Keyword-balanced 3-phase system, cable derating, conductor sizing, harmonic analysis, neutral current

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Harmonics Modeling of Office Equipments Using Matlab and Simulink

Harmonic current pollution is a one of the major power quality problem in electrical power systems. In office buildings one of the main harmonic sources is a large numbers of computer loads. Especially, personal computers apply harmonic distortions to their power supply systems. In this study, harmonics models of equipments, a MATLAB ® code and single-phase Simulink simulation models are develo...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

Electrical Power System Harmonic Analysis Using Adaptive BSS Algorithm

This paper used the gradient blind signal separation algorithm to carry out the electrical power system harmonic signal analysis through the simulation experiment. The experiment result proved that the electrical power system harmonic signal separation based on the gradient algorithm is accurate. Through comparing the separation performance by using the different step size, the adaptive changin...

متن کامل

Classification of emotional speech using spectral pattern features

Speech Emotion Recognition (SER) is a new and challenging research area with a wide range of applications in man-machine interactions. The aim of a SER system is to recognize human emotion by analyzing the acoustics of speech sound. In this study, we propose Spectral Pattern features (SPs) and Harmonic Energy features (HEs) for emotion recognition. These features extracted from the spectrogram ...

متن کامل

Optimal Allocation of the Distributed Active Filters Based on Total Loss Reduction

With the dramatic growth of nonlinear loads, it is desired to improve active filters performance and enhance their capacity. One of the most favorable methods is applying distributed active filter system (DAFS) in which leads to minimizing the cost, weight & size .The main purpose of this paper is to determine the locations and sizes of distributed active filter system (DAFS) With emphasis on r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014