High performance, ion-exchange chromatography of amino-acids in biological fluids using Chromakon 500- performance of the apparatus
نویسندگان
چکیده
The separation and quantitative measurement of aminoacids by ion-exchange chromatography has been in use for many years ]. However, the value of this method is limited by the time required for the analysis: 6 to 23 h. Other methods, such as gas chromatography, give results more rapidly, but do not allow the separation of all amino-acids [2]. The development of cation-exchange resins, capable of resisting high pressure, considerably shortens the time required to perform an analysis. In this study the performance of the Chromakon 500 (Kontron, Switzerland) with a cation-exchange resin (Kontron AS-70 [3]) is evaluated; 39 amino-acids and derivatives can be separated in less than 130 min (170 min including the regeneration time).
منابع مشابه
State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples.
Nowadays, the fast and sensitive high-performance liquid chromatographic (HPLC) analysis of derivatized amino acids is a good alternative to the ion-exchange chromatography (IEC) method for plasma amino acids. However, several precautions have to be taken in order to obtain reliable data on the concentration of amino acids in physiological fluids. These include the collection, centrifugation, s...
متن کاملHIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF SULFUR MUSTARD REACTION WITH AMINO ACIDS AND PROTEINS
The interaction of sulfur mustard with aminoacids and proteins has been investigated in this study. Rats were injected with sublethal doses of sulfur mustard subcutaneously and intraperitoneally. At different time intervals, plasma and urine samples were collected. The binding affinity of sulfur mustard with urinary and plasma proteins and enzymes was studied for the first time using non-i...
متن کاملReview: State-of-the-art of high-performance liquid chromatographic analysis of amino acids in physiological samples
Nowadays, the fast and sensitive high-performance liquid chromatographic I HPLC) analysis of derivatized amino acids is a good alternative to the ion-exchange chromatography (IEC) method for plasma amino acids. However, several precautions have to be taken in order to obtain reliable data on the concentration of amino acids in physiological fluids. These include the collection, centrifugation, ...
متن کاملEffect of Various Levels of Protein in Diet Based on Total and Digestible Amino Acids on Performance of Cobb Strain Broilers
In order to study the effects of various levels of protein in diet based on total and digestible amino acids on performance and carcass traits of broilers, an experiment was conducted as a completely randomized design with 288 broiler chicks from Cobb 500 strain in 6 treatments, each treatment consist of 3 replicates with 16 chicks per replicate. Treatments were the diets as follow: 1) diet for...
متن کاملPerformance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 7 شماره
صفحات -
تاریخ انتشار 1985