Determination of Regimes of the Equivalent Generator Based On Projective Geometry: The Generalized Equivalent Generator
نویسنده
چکیده
Requirements that should be met when determining the regimes of circuits with variable elements are formulated. The interpretation of the variations in the regimes, based on projective geometry, enables adequate expressions for determining and comparing the regimes to be derived. It is proposed to use as the parameters of a generalized equivalent generator of an active two-pole with changeable resistor such load current and voltage which provide the current through this resistor equal to zero. Keywords—equivalent generator, geometric circuits theory, circuits regimes, load characteristics, variable elements.
منابع مشابه
Sensitivity Analysis and Stray Capacitance of Helical Flux Compression Generator with Multi Layer Filamentary Conductor in Rectangular Cross-Section
This paper presents an approach to calculate the equivalent stray capacitance (SC) of n-turn of the helical flux compression generator (HFCG) coil with multi layer conductor wire filaments (MLCWF) in the form of rectangular cross-section. This approach is based on vespiary regular hexagonal (VRH) model. In this method, wire filaments of the generator coil are separated into many very small simi...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملOnline Inertia Constant and Thévenin Equivalent Estimation Using PMU Data
In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...
متن کاملEffect of Different Turbine-generator Shaft Models on the Subsynchronous Resonance Phenomenon in the Double Cage Induction Generator Based Wind Farm
This paper focuses on the turbine-generator shaft models of double-cage Induction Generator (IG) based wind farm and its influence on the sub-synchronous resonance phenomenon. For this purpose, six different shaft models as 6-mass, 4-mass, 3-mass I, 3-mass II, 2-mass and 1-mass models are considered for double-cage IG wind-turbine. By using the linear modal analysis method, the effects of the d...
متن کاملA new design for PID controller by considering the operating points changes in Hydro-Turbine Connected to the equivalent network by using Invasive Weed Optimization (IWO) Algorithm
This paper presents a new optimization algorithm to design an optimal proportional, integral, derivative (PID) controller in hydro-turbine generator governor for damping output frequency oscillations. In this research, we utilize a stochastic and optimal based PID controller to control frequency-response of the hydro turbine. The proposed algorithm is employed to design an optimal PID controlle...
متن کامل