Development of a sensitive and rapid method for the measurement of total microbial activity using Fluorescein Diacetate (FDA) in a range of soils
نویسندگان
چکیده
Fluorescein diacetate (FDA) hydrolysis is widely accepted as an accurate and simple method for measuring total microbial activity in a range of environmental samples, including soils. Colourless fluorescein diacetate is hydrolysed by both free and membrane bound enzymes, releasing a coloured end product fluorescein which can be measured by spectrophotometry. The current method for measuring FDA hydrolysis in soils is limited in its application. FDA activity was very low in sandy and clayey soils. The low activity observed for these soil types was made difficult to measure by the original authors’ choice of solvent for terminating the hydrolysis reaction. Acetone (50% v/v) was found to be most efficient at stopping the hydrolysis reaction. During this study acetone (50% v/v) was found to cause a decrease of approximately 37% in the absorbance of fluorescein produced by the soil samples measured. Although this colour loss is independent of initial fluorescein concentration, it makes the measurement of FDA hydrolytic activity extremely difficult in soils with low microbial activity i.e. sandy and/or clayey soils. Chloroform/methanol (2:1 v/v) was found to successfully stop the hydrolysis reaction for up to 50 min in a range of soil samples without causing the loss of colour observed with acetone. By changing the solvent used for terminating the hydrolysis reaction, low activity soils could be measured successfully. Other parameters of the hydrolysis reaction were optimised for the measurement of soil samples including effect of pH, optimum temperature of incubation, amount of soil, time of incubation, amount of substrate and preparation of suitable standards. A new, more sensitive method is proposed adapted from the original method, which provides a more accurate determination of FDA hydrolysis in a wide range of soils.
منابع مشابه
Fluorescein diacetate hydrolysis as a measure of total microbial activity in soil and litter.
Spectrophotometric determination of the hydrolysis of fluorescein diacetate (FDA) was shown to be a simple, sensitive, and rapid method for determining microbial activity in soil and litter. FDA hydrolysis was studied in soil and straw incubated for up to 3 h. Hydrolysis was found to increase linearly with soil addition. FDA hydrolysis by pure cultures of Fusarium culmorum increased linearly wi...
متن کاملAssessment of fluorescein diacetate hydrolysis as a measure of total esterase activity in natural stream sediment biofilms
I applied the fluorescein diacetate (FDA) hydrolysis technique as a rapid and sensitive estimator of total esterase activity in stream sediment biofilms. I investigated the effects of temperature, pH and incubation time and optimized the assay for low blanks and high fluorescein extraction. The FDA procedure was precise (c.v. = 4.15%) and could detect 10 nM fluorescein. Spatial patterns of este...
متن کاملAssay for fluorescein diacetate hydrolytic activity: Optimization for soil samples
With the increased interest in integrated soil bioecosystem studies, there is a need to have a method of measuring overall microbial activity potential. Hydrolysis of fluorescein diacetate [3 0,6 0-diacetylfluorescein (FDA)] has been suggested as a possible method because the ubiquitous lipase, protease, and esterase enzymes are involved in the hydrolysis of FDA. Following hydrolysis of FDA, fl...
متن کاملDEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES
Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...
متن کاملRapid susceptibility testing of Mycobacterium tuberculosis (H37Ra) by flow cytometry.
The resurgence of tuberculosis has caused considerable effort to be focused on the development of rapid methods for determining the susceptibility of Mycobacterium tuberculosis to antimycobacterial agents. We demonstrated that susceptibility testing of M. tuberculosis can be accomplished rapidly by using flow cytometry. Results of tests were available within 24 h after M. tuberculosis organisms...
متن کامل