Modelling the impact of retention-detention units on sewer surcharge and peak and annual runoff reduction.

نویسندگان

  • Luca Locatelli
  • Søren Gabriel
  • Ole Mark
  • Peter Steen Mikkelsen
  • Karsten Arnbjerg-Nielsen
  • Heidi Taylor
  • Britta Bockhorn
  • Hauge Larsen
  • Morten Just Kjølby
  • Anne Steensen Blicher
  • Philip John Binning
چکیده

Stormwater management using water sensitive urban design is expected to be part of future drainage systems. This paper aims to model the combination of local retention units, such as soakaways, with subsurface detention units. Soakaways are employed to reduce (by storage and infiltration) peak and volume stormwater runoff; however, large retention volumes are required for a significant peak reduction. Peak runoff can therefore be handled by combining detention units with soakaways. This paper models the impact of retrofitting retention-detention units for an existing urbanized catchment in Denmark. The impact of retrofitting a retention-detention unit of 3.3 m³/100 m² (volume/impervious area) was simulated for a small catchment in Copenhagen using MIKE URBAN. The retention-detention unit was shown to prevent flooding from the sewer for a 10-year rainfall event. Statistical analysis of continuous simulations covering 22 years showed that annual stormwater runoff was reduced by 68-87%, and that the retention volume was on average 53% full at the beginning of rain events. The effect of different retention-detention volume combinations was simulated, and results showed that allocating 20-40% of a soakaway volume to detention would significantly increase peak runoff reduction with a small reduction in the annual runoff.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a Comparison Study Between the Joint Probability Approach and Time Series Rainfall Modelling in Coastal Detention Pond Analysis (RESEARCH NOTE)

In tidally affected coastal catchments detention pond should be provided to store flood surface water. A comparison between the full simulation approach based on the joint probability method and time series rainfall modeling via the annual maximum of pond level was undertaken to investigate the assumptions of independence between variables that are necessary in the joint probability method. The...

متن کامل

Estimated height and peak runoff rate in a stream erosion in Kojoor region Nowshahr – North Alborz

Flooding is a natural hazard events and Survey data from the annual losses due to flood in Iran and the world show the extent of the flood damage caused on natural and human resources. To estimate height of the runoff and discharge maximum in basins and stream erosion, there are various experimental methods and mathematical models that one of these models, SCS model is. Thus, the aim of this st...

متن کامل

Selection of Design Events in Tidally Affected Detention Pond Systems (RESEARCH NOTE)

In this paper the development of a single set of design parameters of the sizing of the tidally affected detention pond system was analyzed and tested. The approach uses critical duration single storm event of specified return period, together with a single harmonic tide. The design flood level is then the aggregate of the levels obtained using the system model with the four phase lags between ...

متن کامل

Design of Integrated Bioinfiltration-Detention Urban Retrofits with Design Storm and Continuous Simulation Methods

This article presents the elements involved in the design of a bioretention planter/trench infiltration-detention system as part of a very large-scale urban retrofit project. The prototype system was designed to intercept all of the runoff from a synthetic 5.08-mm 24-h rainfall event. Diverted flows were conveyed into bioretention planter for treatment. The bioretention systems were fingerprint...

متن کامل

Efficiency of source control systems for reducing runoff pollutant loads: feedback on experimental catchments within Paris conurbation.

Three catchments, equipped with sustainable urban drainage systems (SUDS: vegetated roof, underground pipeline or tank, swale, grassed detention pond) for peak flow mitigation, have been compared to a reference catchment drained by a conventional separate sewer system in terms of hydraulic behaviour and discharged contaminant fluxes (organic matter, organic micropollutants, metals). A runoff an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water science and technology : a journal of the International Association on Water Pollution Research

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2015