Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks
نویسندگان
چکیده
BACKGROUND Efficacy and high availability of surgery techniques for refractive defect correction increase the number of patients who undergo to this type of surgery. Regardless of that, with increasing age, more and more patients must undergo cataract surgery. Accurate evaluation of corneal power is an extremely important element affecting the precision of intraocular lens (IOL) power calculation and errors in this procedure could affect quality of life of patients and satisfaction with the service provided. The available device able to measure corneal power have been tested to be not reliable after myopic refractive surgery. METHODS Artificial neural networks with error backpropagation and one hidden layer were proposed for corneal power prediction. The article analysed the features acquired from the Pentacam HR tomograph, which was necessary to measure the corneal power. Additionally, several billion iterations of artificial neural networks were conducted for several hundred simulations of different network configurations and different features derived from the Pentacam HR. The analysis was performed on a PC with Intel® Xeon® X5680 3.33 GHz CPU in Matlab® Version 7.11.0.584 (R2010b) with Signal Processing Toolbox Version 7.1 (R2010b), Neural Network Toolbox 7.0 (R2010b) and Statistics Toolbox (R2010b). RESULTS AND CONCLUSIONS A total corneal power prediction error was obtained for 172 patients (113 patients forming the training set and 59 patients in the test set) with an average age of 32 ± 9.4 years, including 67% of men. The error was at an average level of 0.16 ± 0.14 diopters and its maximum value did not exceed 0.75 dioptres. The Pentacam parameters (measurement results) providing the above result are tangential anterial/posterior. The corneal net power and equivalent k-reading power. The analysis time for a single patient (a single eye) did not exceed 0.1 s, whereas the time of network training was about 3 s for 1000 iterations (the number of neurons in the hidden layer was 400).
منابع مشابه
همبستگی آستیگماتیسم رفرکتیو، قرنیهای و لنتیکولار در افراد داوطلب جراحی رفرکتیو
Background and purpose: Astigmatism is a common optical dysfunction, effective on various visual outcomes and one of the important criteria of refractive surgery. The aim of present study was to evaluate the correlation between refractive, corneal and residual astigmatism in refractive surgery candidates. Materials and methods: In this cross-sectional descriptive, analytical study, 200 patient...
متن کاملAnterior Elevation Maps as the Screening Test for the Ablation Power of Previous Myopic Refractive Surgery
PURPOSE We classified the Orbscan anterior elevation maps in normal eyes (under myopic, emmetropic and hyperopic conditions) and in those after myopic refractive surgery. We did this classification to demonstrate how Orbscan anterior elevation maps are useful in screening for the existence and extent of previous myopic refractive surgery. Such a classification can help clinicians interpret preo...
متن کاملEstimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography
PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subseq...
متن کاملCorneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery.
PURPOSE To evaluate the accuracy of central corneal power measurements by Scheimpflug imaging (Pentacam) for eyes that had corneal refractive surgery. METHODS This study comprised two groups: a pilot group of 100 eyes with prior hyperopic or myopic LASIK that did not have cataract surgery, and a test group of 41 eyes with prior radial keratotomy (RK) and cataract surgery. In the pilot group, ...
متن کاملDistribution of axial, corneal, and combined ametropia in a refractive surgery unit.
PURPOSE To group eyes in our refractive surgery unit on the basis of the origin of their ametropia and to assess the percentage of eyes in the different groups. METHODS Refractive parameters and the axial eye length (AL) of 131 eyes of 131 persons with different refraction were measured. The eyes were initially classified into five groups on the basis of the grade of their ametropia: hypermet...
متن کامل