Validation of multi-channel auditory steady-state response in adults with sensorineural hearing loss.
نویسندگان
چکیده
OBJECTIVE For various medico-legal and financial reasons, some patients may clinically demonstrate an exaggerated hearing loss that varies in degree, nature and laterality. The purpose of this study was to evaluate whether multi-channel auditory steady-state response measurement can be used as an objective test of auditory thresholds in adults with sensorineural hearing loss. STUDY DESIGN AND SETTING This was a prospective, comparative, experimental research design study conducted in an academic medical centre. From January to June 2007, 142 subjects (284 ears) with varying degrees of sensorineural hearing loss were included. Four commonly used frequencies (500, 1000, 2000 and 4000 Hz) were evaluated. Both pure tone thresholds and multi-channel auditory steady-state response thresholds were obtained for each ear in all subjects. The correlation of auditory steady-state response thresholds and pure tone thresholds was assessed. The time taken for multi-channel auditory steady-state response testing was also recorded. RESULTS Results for multi-channel auditory steady-state response thresholds and pure tone thresholds were compared for each test frequency. A difference of less than 15 dB was found in 71 per cent of patients, while a difference of less than 20 dB was found in 83 per cent. Correlation between auditory steady-state response thresholds and pure tone thresholds, expressed as the correlation coefficient (r), was 0.89, 0.95, 0.96 and 0.97 at 500, 1000, 2000 and 4000 Hz, respectively. The strength of the relationship between auditory steady-state response thresholds and pure tone thresholds increased with increasing frequency and increasing degree of hearing loss. The recorded auditory steady-state response thresholds were used to calculate regression lines predicting pure tone threshold results. The mean estimated pure tone thresholds calculated from these regression lines were all within 10 dB of the actual recorded pure tone thresholds. The average multi-channel auditory steady-state response test duration was 42 minutes per patient. CONCLUSION Measurement of multi-channel auditory steady-state response could be a powerful, convenient electro-physiological examination with which to objectively certify clinical hearing impairment in adults.
منابع مشابه
Assessment of the Prevalence of Hearing Impairment in Neonates Born in Imam Reza, Ghaem and OM-Albanin Hospitals of Mashhad
Introduction: The prevalence of hearing loss in neonates is 2-5 out of every 1,000 live births. Global Health Committee, American Academy of Otolaryngology, and American Academy of Pediatrics have recommended that hearing loss in infants be identified, and treated when possible, prior to 6 months of age. This study was designed with the aim to screen the hearing of neonates in Mashhad, Iran. Me...
متن کاملیافتههای پاسخ برانگیخته پایدار شنوایی در بزرگسالان مبتلا به نوروپاتی/ناهمزمانی شنوایی
Background & Aim: Auditory steady state response(ASSR) is an auditory evoked response that has received a lot of attention nowadays. At present, ASSR is mostly used to estimate pure-tone thresholds. Clinical evidence of ASSR in combination with findings for auditory middle latency response (AMLR) and 40 Hz response support the assumption that based on stimulus modulation rate, the ASSR anat...
متن کاملRisk Factors for Sensorineural Hearing Loss in Neonatal Hyperbilirubinemia
Introduction: Hyperbilirubinemia is a common neonatal problem with toxic effects on the nervous system that can cause hearing impairment. This study was conducted to assess the risk factors for sensorineural hearing loss and other coexisting problems in icteric infants. Materials and Methods: In a case-control study, 200 term infants with bilirubin levels higher than 20 mg/dl admitted to the...
متن کاملAuditory Memory deficit in Elderly People with Hearing Loss
Introduction: Hearing loss is one of the most common problems in elderly people. Functional side effects of hearing loss are various. Due to the fact that hearing loss is the common impairment in elderly people; the importance of its possible effects on auditory memory is undeniable. This study aims to focus on the hearing loss effects on auditory memory. Materials and Methods: Dichotic Audi...
متن کاملاثر اختلالات دستگاه شناختی و دستگاه شنوایی مرکزی بر میزان بهرهمندی از وسایل تقویتکننده شنوایی در سالمندان
Objectives: Older adults show many difficulties of speech perception in noisy situations due to peripheral and central auditory impairments, and cognitive dysfunctions. One of the most common rehabilitative procedures for older adults with hearing loss is amplification. However, there is some evidence of dissatisfaction of amplification in older adults. Methods & Materials: We assessed cogni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of laryngology and otology
دوره 123 1 شماره
صفحات -
تاریخ انتشار 2009