Arterial blood gas reference values for sea level and an altitude of 1,400 meters.

نویسندگان

  • R O Crapo
  • R L Jensen
  • M Hegewald
  • D P Tashkin
چکیده

Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

BACKGROUND Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydro...

متن کامل

[Arterial blood gases in clinically healthy adults living at 3,350 meters of altitude].

OBJECTIVES To determine the normal values of arterial blood gases in clinically healthy adults living at 3,350 meters of altitude. MATERIALS AND METHODS The study was conducted in the Santiago district of Cusco, Peru at 3,350 meters of altitude with a sample of 118 subjects determined in a previous pilot study and selected by convenience sampling. The sample included individuals between 20-59...

متن کامل

Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.

Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the ...

متن کامل

Albnormal Circulatory Responses to High Altitude in Subjects with a Previous History of High - Altitude Pulmonary Edema

In five men with a history of susceptibility to high-altitude pulmonary edema (HAPE), hemodynamics and pulmonary gas exchange were measured at sea level, and again 24 hours following ascent to an altitude of 3,100 m. At sea level, all findings were essentially normal including a mean pulmonary arterial pressure (Ppa) of 13.8 + 1.9 mm Hg. None of the subjects developed clinically detectable pulm...

متن کامل

Accuracy of Handheld Blood Glucose Meters at High Altitude

BACKGROUND Due to increasing numbers of people with diabetes taking part in extreme sports (e.g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior studies reported bias in blood glucose measurements using different BGMs at high altitude. We hypothe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 160 5 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1999