Standardization of 123I-meta-iodobenzylguanidine myocardial sympathetic activity imaging: phantom calibration and clinical applications
نویسندگان
چکیده
PURPOSE Myocardial sympathetic imaging with 123I-meta-iodobenzylguanidine (123I-mIBG) has gained clinical momentum. Although the need for standardization of 123I-mIBG myocardial uptake has been recognized, the availability of practical clinical standardization approaches is limited. The need for standardization includes the heart-to-mediastinum ratio (HMR) and washout rate with planar imaging, and myocardial defect scoring with single-photon emission computed tomography (SPECT). METHODS The planar HMR shows considerable variation due to differences in collimator design. These camera-collimator differences can be overcome by cross-calibration phantom experiments. The principles of these cross-calibration phantom experiments are summarized in this article. 123I-mIBG SPECT databases were compiled by Japanese Society of Nuclear Medicine working group. Literature was searched based on the words "123I-mIBG quantification method", "standardization", "heart-to-mediastinum ratio", and its application to "risk model". RESULTS Calibration phantom experiments have been successfully performed in Japan and Europe. The benefit of these cross-calibration phantom experiments is that variation in the HMR between institutions is minimized including low-energy, low-medium-energy and medium-energy collimators. The use of myocardial 123I-mIBG SPECT can be standardized using 123I-mIBG normal databases as a basis for quantitative evaluation. This standardization method can be applied in cardiac event prediction models. CONCLUSION Standardization of myocardial 123I-mIBG outcome parameters may facilitate a universal implementation of myocardial 123I-mIBG scintigraphy.
منابع مشابه
Prediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy
Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...
متن کاملCardiac sympathetic activity in hypertrophic cardiomyopathy and Tako-tsubo cardiomyopathy
123I-meta-iodobenzylguanidine (123I-mIBG) scintigraphy has been established as an important technique to evaluate cardiac sympathetic function and it has been shown to be of clinical value, especially for the assessment of prognosis, in many cardiac diseases. The majority of 123I-mIBG scintigraphy studies have focused on patients with cardiac dysfunction due to hypertension, ischemic heart dise...
متن کاملUptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease
Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...
متن کاملRelation between myocardial response to dobutamine stress and sympathetic nerve activation in patients with idiopathic dilated cardiomyopathy: a comparison of 123I-MIBG scintigraphic and echocardiographic data.
It is likely that a close association exists between findings obtained by two methods: dobutamine stress echocardiography and 123I-MIBG scintigraphy. Both of these methods are associated with beta-adrenergic receptor mechanisms. This study was conducted to demonstrate the relation between myocardial response to dobutamine stress and sympathetic nerve release of norepinephrine in the failing hea...
متن کاملDiagnostic Accuracy of 123I-Meta-Iodobenzylguanidine Myocardial Scintigraphy in Dementia with Lewy Bodies: A Multicenter Study
BACKGROUND AND PURPOSE Dementia with Lewy bodies (DLB) needs to be distinguished from Alzheimer's disease (AD) because of important differences in patient management and outcome. Severe cardiac sympathetic degeneration occurs in DLB, but not in AD, offering a potential system for a biological diagnostic marker. The primary aim of this study was to investigate the diagnostic accuracy, in the ant...
متن کامل