[Evaluation of time dependency of the acetazolamide effect on cerebral hemodynamics as measured by 99mTc-ECD single-photon emission computed tomography].
نویسندگان
چکیده
PURPOSE Kuwabara et al. have examined the cerebral artery dilation with acetazolamide (ACZ) challenge test using PET. And, they reported that ACZ reaction came out time dependently. We have developed a unique SPECT's method using Technetium-99m ethyl cysteinate dimer (99mTc-ECD) to verify the results obtained by Kuwabara et al. METHOD 1000 MBq of 99mTc-ECD was exactly divided into three syringes. Each of which was intravenous infused (i.v.) at rest, 7.5, and 20 minutes after ACZ administration. Data collection was started using dynamic SPECT immediately after 99mTc-ECD i.v. at rest. Using necessary data only, SPECT images representing each of the three 99mTc-ECD i.v. was reconstructed. SPECT counts were obtained by the ROI method from each images to calculate relative CBF from rest to 7.5 and 20 minutes after ACZ administration. RESULT The 18 hemispheres of nine patients in the negative control group in whom ACZ was not loaded. CBF was stable during the three evaluation. The measurement error our method was estimated as small. The 18 hemispheres of nine patients in the positive control group who has normal vasodilatory reserve, CBF was increased by 26.2 +/- 8.1% at 7.5 minutes and 29.3 +/- 13.1% at 20 minutes after ACZ administration. Seven patients with and chronic stage unilateral internal carotid artery severe stenosis and/or occlusion were evaluated as the test group. Case of unaffected side, CBF was increased by 17.6 +/- 6.9% at 7.5 minutes and 24.8 +/- 11.3% 20 minutes after ACZ administration. And, increase rate of CBF in the affected side was 2.8 +/- 1.6% at 7.5 minutes and 17.3 +/- 5.0% at 20 minutes after ACZ administration. In the affected side, timing of the maximum CBF increase caused by ACZ was remarkably delayed. CONCLUSION Our method based on 99mTc-ECD SPECT also revealed delayed cerebral artery dilation in the affected side. It was suggested that ACZ reaction came out time dependently, as reported by Kuwabara et al.
منابع مشابه
Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کامل99mTc-bicisate and 99mTc-HMPAO SPECT imaging in early spontaneous reperfusion of cerebral embolism.
Two patients with a cerebral embolism were evaluated by using both 99mTc-ethyl cysteinate dimer (ECD, or Bicisate) and 99mTc-hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). In one patient, 99mTc-ECD SPECT images revealed hypoactivity in a reflow hyperemic area where an infarct was seen later on CT scans. In another patient, a reperfused area showed hyp...
متن کامل99mTc-HMPAO-SPECT with acetazolamide challenge to detect hemodynamic compromise in occlusive cerebrovascular disease.
BACKGROUND AND PURPOSE Insufficiency of collateral supply may lead to low-flow infarcts in severe occlusive cerebrovascular disease. The aim of this study was to evaluate the feasibility of technetium-99m-labeled hexamethylpropyleneamine oxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) to assess hemodynamic compromise in the anterior circulation. METHODS Cerebral blood f...
متن کاملThe Effect of Morphine on Regional Cerebral Blood Flow Measured by 99mTc-ECD SPECT in Dogs
To gain insights into the working mechanism of morphine, regional cerebral blood flow (rCBF) patterns after morphine administration were assessed in dogs. In a randomized cross-over experimental study, rCBF was estimated with 99mTc-Ethylcysteinate Dimer single photon emission computed tomography in 8 dogs at baseline, at 30 minutes and at 120 minutes after a single bolus of morphine. Perfusion ...
متن کاملEvaluation of the Efficacy of Standardized Uptake Value (SUV)-shape Scheme for Thyroid Volume Determination in Graves’ Disease: A Comparison with Ultrasonography
Objective(s): In this study, we aimed to evaluate the efficacy of thyroid volume measurement using 99mTc pertechnetate single-photon emission computed tomography (SPECT) images, acquired by the standardized uptake value (SUV)-shape scheme designed by our expert team.Methods: A total of 18 consecutive patients with Graves’ disease (GD) were subjected to both ultrasonographic and 99mTc pertechnet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kaku igaku. The Japanese journal of nuclear medicine
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2001