Framing Failures in Wood-Frame Hip Roofs under Extreme Wind Loads

نویسندگان

  • Sarah A. Stevenson
  • Gregory A. Kopp
  • Ayman M. El Ansary
چکیده

Wood-frame residential roof failures are among the most common and expensive types of wind damage. Hip roofs are commonly understood to be more resilient during extreme wind in relation to gable roofs. However, inspection of damage survey data from recent tornadoes has revealed a previously unstudied failure mode in which hip roofs suffer partial failure of the framing structure. In the current study, evidence of partial framing failures and statistics of their occurrence are explored and discussed, while the common roof design and construction practice are reviewed. Two-dimensional finite element models are developed to estimate the element-level load effects on hip roof trusses and stick-frame components. The likelihood of failure in each member is defined based on relative demand-to-capacity ratios. Trussed and stick-frame structures are compared to assess the relative performance of the two types of construction. The present analyses verify the common understanding that toenailed roof-to-wall connections are likely to be the most vulnerable elements in the structure of a wood-frame hip roof. However, the results also indicate that certain framing members and connections display significant vulnerability under the same wind uplift, and the possibility of framing failure is not to be discounted. Furthermore, in the case where the roof-to-wall connection uses hurricane straps, certain framing members and joints become the likely points of failure initiation. The analysis results and damage survey observations are used to expand the understanding of wood-frame residential roof failures, as they relate to the Enhanced Fujita Scale and provide assessment of potential gaps in residential design codes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural Quality Assurance of Wood Light - Frame Construction Subject to Extreme Wind Hazards

The poor performance of wood light-frame construction (WLFC) during recent hurricanes disputed the efficacy of the wood light-frame building process in high wind environments. Deficiencies observed in the wake of Hurricane Andrew (1992) in particular suggest that solutions to the problem must consider human-based factors within the building process. The objective of this thesis is to develop an...

متن کامل

Fragility Assessment of Light-Frame Wood Construction Subjected to Wind and Earthquake Hazards

A fragility analysis methodology is developed for assessing the response of light-frame wood construction exposed to stipulated extreme windstorms and earthquakes. Performance goals and limit states (structural and nonstructural) are identified from a review of the performance of residential construction during recent hurricanes and earthquakes in the United States. Advanced numerical modeling ...

متن کامل

State of the Art Volume Estimation of Extreme Wind Speeds

Extreme wind loads used in design (e.g., the 50-yr wind load) and include nominal design wind loads ultimate wind loads. This paper briefly reviews the relationship between extreme wind loads and extreme wind speeds, assessments of epochal versus ‘peak-overthreshold’ approaches for estimating extreme non-tornadic winds in areas not subjected to tropical storms, and methods for estimating extrem...

متن کامل

Bridge Fatigue Damage Assessment under Vehicle and Non-Stationary Hurricane Wind

During hurricane events, large stress cycles from the non-stationary wind and dynamic vehicle loads could possibly induce damage initiations and propagations. Utilizing the non-stationary wind field modeling techniques and the recent developed vehicle-bridge-wind dynamic analysis framework, this paper initiates the bridge fatigue damage assessment of bridges under vehicle and non-stationary ext...

متن کامل

Forces and Moments on Flat Plates of Small Aspect Ratio with Application to PV Wind Loads and Small Wind Turbine Blades

To improve knowledge of the wind loads on photovoltaic structures mounted on flat roofs at the high angles required in high latitudes, and to study starting flow on low aspect ratio wind turbine blades, a series of wind tunnel tests were undertaken. Thin flat plates of aspect ratios between 0.4 and 9.0 were mounted on a sensitive three-component instantaneous force and moment sensor. The Reynol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018