Endothelial dysfunction in diabetic patients with abnormal myocardial perfusion in the absence of epicardial obstructive coronary artery disease.

نویسندگان

  • Roxana Djaberi
  • Jos op 't Roodt
  • Joanne D Schuijf
  • Ton J Rabelink
  • Eelco J de Koning
  • Alberto M Pereira
  • Marcel P Stokkel
  • Jan W Smit
  • Jeroen J Bax
  • J Wouter Jukema
چکیده

UNLABELLED In patients with diabetes mellitus, myocardial perfusion defects are often observed in the absence of obstructive epicardial coronary artery disease (CAD), thereby presenting a diagnostic problem. We hypothesized that these perfusion abnormalities may be explained by endothelial dysfunction or occult coronary atherosclerosis. METHODS Prospectively, 130 asymptomatic patients with diabetes mellitus underwent cardiovascular screening by coronary artery calcium (CAC) scoring, multislice CT coronary angiography, and myocardial perfusion imaging by SPECT. Multislice CT images were evaluated for the presence of obstructive epicardial CAD (>or=50% luminal narrowing). To quantify abnormal myocardial perfusion on SPECT images, we determined the summed stress score for each patient. The presence of abnormal myocardial perfusion was defined as a summed stress score of 3 or more. In addition, flow-mediated dilatation of the brachial artery, a marker of endothelial function, was determined using ultrasonography. RESULTS In 35 patients (27%), obstructive epicardial CAD was observed on multislice CT, and these patients were excluded from further analysis. In the remaining 95 patients, abnormal myocardial perfusion was observed in 30 (32%) of patients. Flow-mediated dilatation was significantly lower in patients with abnormal myocardial perfusion (3.6% +/- 2.4%) than in those with normal myocardial perfusion (6.4% +/- 2.6%) (P < 0.001). Importantly, flow-mediated dilatation remained a significant predictor of the extent of abnormal myocardial perfusion after correction for cardiovascular risk factors and CAC score (P < 0.001). In contrast, no association was observed between nonobstructive plaque burden as reflected by CAC scores and extent of abnormal myocardial perfusion. CONCLUSION In patients with diabetes mellitus, myocardial perfusion abnormalities in the absence of obstructive epicardial CAD are associated with endothelial dysfunction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different aspects of transient ischemic dilation

  Transient ischemic left ventricular dilation (TID) is a marker of severe and extensive coronary artery disease as well as an increased risk of adverse outcomes. The patients with more severe and extensive ischemia, multivessel-type of perfusion abnormality as well as patients with left anterior descending artery (LAD) territory perfusion abnormality have more probab...

متن کامل

The myocardial perfusion scintigraphy in asymptomatic diabetic patients

Introduction: Asymptomatic diabetic patients are at increased risk of cardiovascular complications. Myocardial perfusion scan may be effective in risk evaluation in this population. Methods: 106 asymptomatic diabetic patients (age: min: 37, max: 82, mean: 57.73±8.88), including 56 females (52.8%) and 50 males (47.2%) were enrolled in the study. Myocardial perfusion scintigraphy was performed b...

متن کامل

Comparison of dipyridamole – induced electrocardiographic changes and myocardial perfusion imaging in diagnosis of coronary artery disease [Persian]

Introduction: This study evaluated the diagnostic value of the dipyridamole induced electrocardiuogram (ECG) cahnges, comparing with myocardial perfusion imaging. Materials and Methods: 222 patinets were studied with dipyridamole infusion (based on ECG criteria) as well as Dipyridamole-myocardial perfusion imaging (MPI). Results: Abnormal dipyridamole test and abnormal MPI were noted in 1...

متن کامل

Clinical value and severity of myocardial perfusion defects in asymptomatic diabetic patients with negative or weakly positive exercise treadmill test

Objective: Although coronary artery disease (CAD) is the leading cause of death in type 2 diabetic patients, it is frequently asymptomatic. Myocardial perfusion imaging (MPI) is reported to show ischemia in a significant number of asymptomatic diabetic patients. We studied the prevalence and severity of myocardial perfusion defects in asymptomatic diabetic patients and its clinical impact. Meth...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2009