Automated analysis of strain rate and strain: feasibility and clinical implications.

نویسندگان

  • Charlotte Bjork Ingul
  • Hans Torp
  • Svein Arne Aase
  • Sigrid Berg
  • Asbjorn Stoylen
  • Stig A Slordahl
چکیده

BACKGROUND This study evaluated 3 new automated methods, based on a combination of speckle tracking and tissue Doppler, for the analysis of strain rate (SR) and strain. Feasibility and values for peak systolic strain rate (SR s ) and end-systolic strain (S es ) were assessed. METHODS Thirty patients with myocardial infarction and 30 normal subjects were examined. Customized software with automatic definition of segments was used for automated measurements. SR s and SR es were measured over each segment simultaneously and identified automatically. The study compared tissue Doppler-based SR and strain measurements without (method 1) and with segment tracking (method 2) to speckle tracking-based measurements (method 3). For tracking, speckle tracking and tissue Doppler were used in combination. Standard manual analysis was used as a reference. RESULTS The automated analysis (16 segments, 3 apical views) required 2 minutes; manual analysis took 11 minutes. Accuracy was compared in 56 segments (28 mid-infarcted and 28 normal) from 28 patients and was 93.9% for method 1, 93.8% for method 2, 95.8% for method 3, and 96.2% for the manual method. In the normal group, mean SR s (0.27 s -1 ) was less with method 3 than with the other methods ( P < .001). CONCLUSIONS Our findings indicate that automated analysis of SR and strain, with some manual adjustment, is feasible and quicker than manual analysis. Diagnostic accuracy was similar with all methods. SR s was lower in the speckle tracking-based method than in the Doppler-based methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Analysis of deep drawing process to predict the forming severity considering inverse finite element and extended strain-based forming limit diagram

An enhanced unfolding Inverse Finite Element Method (IFEM) has been used together with an extended strain-based forming limit diagram (EFLD) to develop a fast and reliable approach to predict the feasibility of the deep drawing process of a part and determining where the failure or defects can occur. In the developed unfolding IFEM, the meshed part is properly fold out on the flat sheet and tre...

متن کامل

بررسی تجربی رفتار حساس به نرخ کرنش پوسته های استوانه ای ساخته شده از آلیاژآلومینیومی 6063 تحت بارگذاری فشاری داخلی(علمی-پژوهشی)

The plastic behavior of materials depends on their strain rate sensitivity. The main objective of this paper is the analysis of the effect of strain rate sensitivity on plastic behavior of cylindrical shells under internal pressure loading and hence a large number empirical tests have been conducted on aluminum cylindrical shells. We have also manufactured and used a hydrostatic test machine to...

متن کامل

Characterization of Production and Reproduction Performances in Rhode Island Red-White Strain Chicken

This study aimed to characterize production and reproduction performances in Rhode Island Red-White strain chicken developed and maintained at the Central Avian Research Institute, Izatnagar. Three hundred and forty six fertile eggs were set in automated electric incubation and 234 chicks were investigated in three hatches. The performance data was analyzed by least squares analysis of variance...

متن کامل

Quantitative analysis of thermo-mechanical behavior in 414 stainless steel using flow curves and processing maps

The hot deformation behavior of a typical martensitic stainless steel containing 2.1% Ni was investigated by means of the compression test in the strain rate range of 0.001-1 s-1 and temperature range of 950-1150 °C. The flow behavior of the steel was evaluated using the flow stress curves and flow softening map and by microstructural investigation. Taking into account of the strain effect on t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2005