Simultaneous and Direct Determination of Vancomycin and Cephalexin in Human Plasma by Using HPLC-DAD Coupled with Second-Order Calibration Algorithms

نویسندگان

  • Le-Qian Hu
  • Chun-Ling Yin
  • Ya-Hui Du
  • Zhi-Peng Zeng
چکیده

A simple, rapid, and sensitive method for the simultaneous determination of vancomycin and cephalexin in human plasma was developed by using HPLC-DAD with second-order calibration algorithms. Instead of a completely chromatographic separation, mathematical separation was performed by using two trilinear decomposition algorithms, that is, PARAFAC-alternative least squares (PARAFAC-ALSs) and self-weight-alternative-trilinear-decomposition- (SWATLD-) coupled high-performance liquid chromatography with DAD detection. The average recoveries attained from PARAFAC-ALS and SWATLD with the factor number of 4 (N = 4) were 101 ± 5% and 102 ± 4% for vancomycin, and 96 ± 3% and 97 ± 3% for cephalexininde in real human samples, respectively. The statistical comparison between PARAFAC-ALS and SWATLD is demonstrated to be similar. The results indicated that the combination of HPLC-DAD detection with second-order calibration algorithms is a powerful tool to quantify the analytes of interest from overlapped chromatographic profiles for complex analysis of drugs in plasma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Simultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration

An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...

متن کامل

GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...

متن کامل

GC-FID and HPLC-DAD Methods for the Determination of Menadione Sodium Bisulphite Directly and by Converting Menadione Sodium Bisulphite to Menadione in Pharmaceutical Preparation

GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012