Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance

نویسندگان

  • Cecile Berteau
  • Orchidée Filipe-Santos
  • Tao Wang
  • Humberto E Rojas
  • Corinne Granger
  • Florence Schwarzenbach
چکیده

AIM The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC) injection pain tolerance. METHODS The study was a single-center, comparative, randomized, crossover, Phase I study in 24 healthy adults. Each participant received six injections in the abdomen area of either a 2 or 3 mL placebo solution, with three different fluid viscosities (1, 8-10, and 15-20 cP) combined with two different injection flow rates (0.02 and 0.3 mL/s). All injections were performed with 50 mL syringes and 27G, 6 mm needles. Perceived injection pain was assessed using a 100 mm visual analog scale (VAS) (0 mm/no pain, 100 mm/extreme pain). The location and depth of the injected fluid was assessed through 2D ultrasound echography images. RESULTS Viscosity levels had significant impact on perceived injection pain (P=0.0003). Specifically, less pain was associated with high viscosity (VAS =12.6 mm) than medium (VAS =16.6 mm) or low (VAS =22.1 mm) viscosities, with a significant difference between high and low viscosities (P=0.0002). Target injection volume of 2 or 3 mL was demonstrated to have no significant impact on perceived injection pain (P=0.89). Slow (0.02 mL/s) or fast (0.30 mL/s) injection rates also showed no significant impact on perceived pain during SC injection (P=0.79). In 92% of injections, the injected fluid was located exclusively in SC tissue whereas the remaining injected fluids were found located in SC and/or intradermal layers. CONCLUSION The results of this study suggest that solutions of up to 3 mL and up to 15-20 cP injected into the abdomen within 10 seconds are well tolerated without pain. High viscosity injections were shown to be the most tolerated, whereas injection volume and flow rates did not impact perceived pain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noxious behaviors from subcutaneous injection of formalin and morphine tolerance effects on the responses of addicted male rats

Formalin as a chemical noxious stimulus evokes a biphasic pain that its second phase as a chronic inflammatory pain is similar to clinical pain. In this study, we used 40 NMRI male rats (250-300 g), and experiments were carried out considering ethical rules. Experiments were performed in normal and morphine addicted rats, the addiction was induced by Leung method. Behaviors of flinching and lic...

متن کامل

Noxious behaviors from subcutaneous injection of formalin and morphine tolerance effects on the responses of addicted male rats

Formalin as a chemical noxious stimulus evokes a biphasic pain that its second phase as a chronic inflammatory pain is similar to clinical pain. In this study, we used 40 NMRI male rats (250-300 g), and experiments were carried out considering ethical rules. Experiments were performed in normal and morphine addicted rats, the addiction was induced by Leung method. Behaviors of flinching and lic...

متن کامل

Numerical analysis of heat transfer in helical tube with the aluminum oxide (Al2O3) nano fluid injection in water

The most important reason for the design of curved tubes is increasing the heat transfer between the fluid and the wall which has provided many applications in various industries such as air conditioning, micro-electric, heat exchangers and etc. The aim of this study is numerical investigation of nano fluids flow in spiral tubes with injection of base fluid in different Reynolds numbers. Accord...

متن کامل

Performance Evaluation of Viscosity Characteristics of Enhanced Preformed Particle Gels (PPGs)

Preformed Particle Gels (PPGs) treatment is one of the most promising solutions to improve conformance control in mature water flooded oil reservoirs. It is very important to be able to evaluate and predict performance of PPGs in porous media. In this paper, we will first introduce new class of enhanced PPGs designed for harsh reservoir conditions (high salinity and temperature) and then pr...

متن کامل

Flow Re-Stabilizing Observation via Air Injection during the Rotating Stall through a Single-stage Axial Compressor by a 2-D Finite-volume Approach

The air-injection as an active flow stabilizing techniques, were numerically examined in current work, during the aerodynamic behavior and the characteristics of an axial compressor. At first, in design condition the characteristic curve was numerically captured for a specified test compressor. The computed results showed good agreements with those obtained from the experiments, to validate the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015