Performance of a photothermal detector with turbid liquids.

نویسندگان

  • Jane Hodgkinson
  • Mark Johnson
  • John P Dakin
چکیده

A closed-cell photothermal detector for aqueous analytes has been evaluated at 254 and 678 nm. We used a detector with a water meniscus as a pressure sensor, whose periodic deflection was measured using a low-finesse optical fiber Fabry-Perot interferometer. Performance was compared with a commercial diode array spectrometer and found to be similar for absorption measurements in nonturbid samples, but the results were affected up to 60 times less by scattered light. Finally the photothermal cell was converted into an integrating cavity using ceramic inserts, showing freedom from scattering-related errors at 678 nm but a degradation in performance at 254 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Theoretical, experimental, and computational aspects of optical property determination of turbid media by using frequency-domain laser infrared photothermal radiometry.

In this work, the optical and thermal properties of tissuelike materials are measured by using frequency-domain infrared photothermal radiometry. This technique is better suited for quantitative multiparameter optical measurements than the widely used pulsed-laser photothermal radiometry (PPTR) because of the availability of two independent signal channels, amplitude and phase, and the superior...

متن کامل

Photothermal deflection spectroscopy and detection.

The theory for a sensitive spectroscopy based on the photothermal deflection of a laser beam is developed. We consider cw and pulsed cases of both transverse and collinear photothermal deflection spectroscopy for solids, liquids, gases, and thin films. The predictions of the theory are experimentally verified, its implications for imaging and microscopy are given, and the sources of noise are a...

متن کامل

Treatment of Highly Turbid Water by Polyaluminum Ferric Chloride (PAFCL)

Background & Aims of the Study: In some situation like rainfall seasons raw water become very turbid so it affected the water treatment plant processes and quality of produced water. Treatment of very high turbid water has some concerns like precursors for disinfection by-products and very loading rate of particle on filter's media and consequently increases in water consumptio...

متن کامل

Multifunctional GQDs-Coated Fe/Bi Nanohybrids for CT/MR Dual Imaging and in vitro Photothermal Therapy

Introduction: The multipurpose nanocomposites have gained growing biomedical attention as promising nanotheranostics to improve The effectiveness of cancer treatment, which concurrently combine advantages of the therapeutic and diagnostic techniques into one nanosystem. The “all-in on” probes not only help to ablate cancerous tumors, but also allow to optimize and monitoring of...

متن کامل

Photothermal excitation for improved cantilever drive performance in tapping mode atomic force microscopy

Photothermal excitation is an alternative cantilever drive mechanism for tapping mode atomic force microscopy. It uses a power-modulated laser focused on the cantilever to directly drive its oscillation, producing cantilever tunes that match the thermal response almost perfectly. This enables quantitatively accurate AFM imaging and viscoelastic nanomechanical mapping in all environments. In add...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 44 20  شماره 

صفحات  -

تاریخ انتشار 2005