Applying a [C]Raclopride Template to Automated Binding Potential Estimation in HRRT Brain PET
نویسندگان
چکیده
Performing kinetic analysis of [C]raclopride PET data typically involves user intervention to identify key volumes of interest, such as the cerebellum for the reference region and the caudate and putamen for regions where the binding potential (BP) needs to be estimated. In many PET centres, this process is neither automated nor standardized, possibly producing discrepancies between centres. Conventionally, MR anatomical images are used to identify the key volumes of interest, but this is difficult to automate robustly, and user intervention can sometimes be required. This work considers instead the use of an anatomically labeled [C]raclopride template, formed from multiple subjects, which has the key advantages of low noise, good resolution and having a highly similar spatiotemporal intensity distribution to any given single subject raclopride scan. This makes the template an excellent target for automated image registration and segmentation. We present a methodology which works on post-reconstruction images, demonstrating an automated and consistent way of identifying key regions of interest (ROIs) and determining binding potential without any MR image or user intervention. The performance of the methodology is evaluated using simulated and real [C]raclopride data. The simplified reference tissue model with the basis function method (SRTM-BFM) was used for the kinetic modeling.
منابع مشابه
Atlas Construction for Dynamic (4D) PET Using Diffeomorphic Transformations
A novel dynamic (4D) PET to PET image registration procedure is proposed and applied to multiple PET scans acquired with the high resolution research tomograph (HRRT), the highest resolution human brain PET scanner available in the world. By extending the recent diffeomorphic log-demons (DLD) method and applying it to multiple dynamic [11C]raclopride scans from the HRRT, an important step towar...
متن کاملComparison of PET template-based and MRI-based image processing in the quantitative analysis of C11-raclopride PET
BACKGROUND Quantitative measures of 11C-raclopride receptor binding can be used as a correlate of postsynaptic D2 receptor density in the striatum, allowing 11C-raclopride positron emission tomography (PET) to be used for the differentiation of Parkinson's disease from atypical parkinsonian syndromes. Comparison with reference values is recommended to establish a reliable diagnosis. A PET templ...
متن کاملComparison of HRRT and HR+ Scanners
Purpose: To directly compare HRRT (high resolution brain) and HR+ (standard wholebody) PET only scanners for quantitative brain studies using three tracers with vastly different tracer distributions. Procedures: Healthy volunteers underwent successive scans on HR+ and HRRT scanners (in random order) using either (R)-[C]verapamil (n=6), [C]raclopride (n=7) or [C]flumazenil (n=7). For all tracers...
متن کاملSegmentation of Striatal Brain Structures from High Resolution PET Images
We propose and evaluate an automatic segmentation method for extracting striatal brain structures (caudate, putamen, and ventral striatum) from parametric (11)C-raclopride positron emission tomography (PET) brain images. We focus on the images acquired using a novel brain dedicated high-resolution (HRRT) PET scanner. The segmentation method first extracts the striatum using a deformable surface...
متن کاملProgressive striatal and cortical dopamine receptor dysfunction in Huntington's disease: a PET study.
We have studied the progression of striatal and extrastriatal post-synaptic dopaminergic changes in a group of 12 patients with Huntington's disease using serial (11)C-raclopride PET, a specific marker of D2 dopamine receptor binding. All patients had two (11)C-raclopride PET scans 29.2 +/- 12.8 months apart, and six of them had a third scan 13.2 +/- 3.9 months later. We found a mean annual 4.8...