Early detection of cystic fibrosis lung disease: multiple-breath washout versus raised volume tests.

نویسندگان

  • Sooky Lum
  • Per Gustafsson
  • Henrik Ljungberg
  • Georg Hülskamp
  • Andrew Bush
  • Siobhán B Carr
  • Rosemary Castle
  • Ah-Fong Hoo
  • John Price
  • Sarath Ranganathan
  • John Stroobant
  • Angie Wade
  • Colin Wallis
  • Hilary Wyatt
  • Janet Stocks
چکیده

BACKGROUND Lung clearance index (LCI), a measure of ventilation inhomogeneity derived from the multiple-breath inert gas washout (MBW) technique, has been shown to detect abnormal lung function more readily than spirometry in preschool children with cystic fibrosis, but whether this holds true during infancy is unknown. OBJECTIVES To compare the extent to which parameters derived from the MBW and the raised lung volume rapid thoraco-abdominal compression (RVRTC) techniques identify diminished airway function in infants with cystic fibrosis when compared with healthy controls. METHODS Measurements were performed during quiet sleep, with the tidal breathing MBW technique being performed before the forced expiratory manoeuvres. RESULTS Measurements were obtained in 39 infants with cystic fibrosis (mean (SD) age 41.4 (22.0) weeks) and 21 controls (37.0 (15.1) weeks). Infants with cystic fibrosis had a significantly higher respiratory rate (38 (10) vs 32 (5) bpm) and LCI (8.4 (1.5) vs 7.2 (0.3)), and significantly lower values for all forced expiratory flow-volume parameters compared with controls. Girls with cystic fibrosis had significantly lower forced expiratory volume (FEV(0.5) and FEF(25-75 )) than boys (mean (95% CI girls-boys): -1.2 (-2.1 to -0.3) for FEV(0.5) Z score; FEF(25-75): -1.2 (-2.2 to -0.15)). When using both the MBW and RVRTC techniques, abnormalities were detected in 72% of the infants with cystic fibrosis, with abnormalities detected in 41% using both techniques and a further 15% by each of the two tests performed. CONCLUSIONS These findings support the view that inflammatory and/or structural changes in the airways of children with cystic fibrosis start early in life, and have important implications regarding early detection and interventions. Monitoring of early lung disease and functional status in infants and young children with cystic fibrosis may be enhanced by using both MBW and the RVRTC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CYSTIC FIBROSIS Early detection of cystic fibrosis lung disease: multiple-breath washout versus raised volume tests

Sooky Lum, Per Gustafsson, Henrik Ljungberg, Georg Hülskamp, Andrew Bush, Siobhán B Carr, Rosemary Castle, Ah-fong Hoo, John Price, Sarath Ranganathan, John Stroobant, Angie Wade, Colin Wallis, Hilary Wyatt, Janet Stocks on behalf of the London Cystic Fibrosis Collaboration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

متن کامل

Early detection of cystic fibrosis lung disease: multiple breath washout vs. raised volume tests

Portex Anaesthesia, Intensive Therapy and Respiratory Medicine Unit, UCL, Institute of Child Health, London. Department of Pediatric Clinical Physiology, Queen Silvia Children’s Hospital, Göteborg, Sweden. Department of Paediatric Respiratory Medicine, Royal Brompton Hospital, London. Department of Child Health, Royal London Hospital, London. Department of Paediatric Respiratory Medicine, Great...

متن کامل

Evaluation of ventilation maldistribution as an early indicator of lung disease in children with cystic fibrosis.

Many children with cystic fibrosis (CF), receiving modern, aggressive CF care, have normal spirometry results. This study aimed to see if homogeneity of ventilation distribution is impaired early in the course of CF lung disease, and if ventilation inhomogeneity is a more frequent finding than abnormal spirometry in children benefiting from modern CF care. The study compared spirometry findings...

متن کامل

Dual gas techniques for peripheral airway function: diffusing the issues

In the quest to investigate small airway function in a range of lung diseases, multiple-breath washout tests have been applied for their potential to represent the most peripheral air spaces [1, 2]. The aim of reducing the burden on the patient has recently also revived interest in the single-breath washout. A single-breath washout test has now been proposed which involves an inhalation of 5% S...

متن کامل

Consensus statement on inert gas washout measurement: at the threshold of clinical use.

I nert gas washout tests including single breath washout (SBW) and multiple breath washout (MBW) have been used for several decades across a wide age range spanning from early infancy to late adulthood. In the past, these lung function tests were typically applied in research settings, assessing lung volume and ventilation distribution in order to gain insight into presence, severity and progre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 2007