Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines

نویسندگان

  • Benjamin Panzram
  • Ines Bertlich
  • Tobias Reiner
  • Tilman Walker
  • Sébastien Hagmann
  • Marc-André Weber
  • Tobias Gotterbarm
چکیده

PURPOSE Tibial radiolucent lines (RL) are commonly seen in cemented unicompartmental knee replacement (UKR). In the postoperative course, they can be misinterpreted as signs of loosening, thus leading to unnecessary revision. Since 2004, a cementless OUKR is available. First studies and registry data have shown equally good clinical results of cementless OUKR compared to the cemented version and a significantly reduced incidence of RL in cementless implants. METHODS This single-centre retrospective cohort study includes the first 30 UKR (27 patients) implanted between 2007 and 2009 with a mean follow-up of 5 years. Clinical outcome was evaluated using the OKS, AKS, range of movement (ROM) and level of pain (VAS). Standard radiologic evaluation was performed at three months, one and five years after surgery. The results five years after implantation were compared to a group of 27 cemented Oxford UKR (OUKR) in a matched-pair-analysis. RESULTS Tibial RL were seen in 10 implants three months after operation, which significantly decreased to five after one year and to three after five years (p = 0.02). RL did not have a significant influence on revision (p = 1.0) or clinical outcome after five years. RL were always partial, never progressive and strictly limited to the tibia. There was no significant difference in the incidence of tibial RL five years after implantation between cemented and cementless implants (cemented: 4, cementless: 3, p = 1.0). CONCLUSIONS After cementless implantation RL were limited to the tibia, partial and never progressive. During short term follow-up the incidence of RL decreased significantly. RL seem to have no influence on clinical outcome and revision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.

Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical signi...

متن کامل

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year.

We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs. At one year there was no difference in clinical ...

متن کامل

The effect of leg alignment on the outcome of unicompartmental knee replacement.

Varus malalignment after total knee replacement is associated with a poor outcome. Our aim was to determine whether the same was true for medial unicompartmental knee replacement (UKR). The anatomical leg alignment was measured prospectively using a long-arm goniometer in 160 knees with an Oxford UKR. Patients were then grouped according to their mechanical leg alignment as neutral (5 degrees t...

متن کامل

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

Medial Unicompartmental Osteoarthritis (MUO) of the Knee: Unicompartmental Knee Replacement (UKR) or Total Knee Replacement (TKR)

The aim of this review article is to analyze the clinical effectiveness of total knee replacement (TKR) compared to unicompartmental knee replacement (UKR) in patients with medial unicompartmental osteoarthritis (MUO) in terms of survival rates, revision rates and postoperative complications. The search engine was MedLine. The keywords used were: medial knee osteoarthritis. Three thousand and n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017