Utility of Cardiac Gating for Pulmonary Perfusion MRI

نویسندگان

  • K. Wang
  • M. Schiebler
  • C. Francois
  • A. Munoz Del Rio
  • F. Korosec
  • S. Fain
چکیده

INTRODUCTION Cardiac motion is a common source of artifacts when imaging the chest with methods such as pulmonary perfusion MRI and pulmonary MR angiography (MRA). To minimize these artifacts, the MR sequence is often ECG-gated such that data are only acquired during a portion of the cardiac cycle when the heart is relatively quiescent; typically during diastole. However, this reduces scan efficiency and requires more complicated patient preparation, including placement of ECG leads. Furthermore, the trade-off between image quality and scan efficiency is application dependent, with some imaging methods more sensitive to cardiac motion than others. The purpose of this study was to determine whether or not cardiac gating improves image quality for pulmonary perfusion MRI using a recently developed method that results in high isotropic spatial resolution, high temporal resolution, and whole chest coverage [1]. If no significant improvement in image quality is seen with cardiac gating, then non-gated scans can be performed to increase scan efficiency and simplify patient preparation. MATERIALS AND METHODS To date, 9 normal volunteers have been recruited for this on-going IRBapproved, HIPAA-compliant prospective study. Each subject was scanned on a 3T clinical scanner (GE Healthcare, Waukesha, WI), using a 32-channel phased array coil and a recently described pulmonary perfusion method incorporating parallel imaging and interleaved variable density sampling [1]. In order to compare a variety of different schemes for minimizing cardiac motion artifact during a single exam, a total 1.5× dose of the blood-pool contrast agent gadofosveset (Lantheus Medical Imaging, N. Billerica, MA) was used. Dynamic imaging was performed during each of 3 injections of 0.5× dose of contrast, followed by acquisitions during the steady-state. The following four gating methods were investigated: (1) nongated; (2) ECG-gated; (3) peripherally-gated; (4) pseudogated. Pseudogating was achieved by setting up the acquisition so that the temporal resolution of scan was equal to 1/(heart rate). In addition, standard elliptical centric (EC) k-space order was compared with an “edge-center-edge” (ECE) order as prior work suggested that ECE order may be advantageous for minimizing cardiac motion [2-4]. Both dynamic and steady state images were reconstructed using view sharing. The images from each subject were randomized before being independently ranked in order of image quality by 3 cardiovascular radiologists. Image ranking rather than absolute scoring was performed in order to force the readers to differentiate the images, which were all very similar in image quality. RESULTS AND DISCUSSION All three readers reported great difficulty in identifying differences in image quality, especially within the lungs. All readers reported relying principally on the fidelity of reconstruction of the bloodmyocardium interface and the aortic root in order to differentiate the images. For example, Fig. 1a presents axial images from two representative volunteers using the 3 different dynamic acquisition schemes. Note the very similar image quality between gated and non-gated methods. No significant differences in rank order were found between the dynamic methods, which included non-gated “edge-centeredge”, non-gated elliptical centric and ECG-gated “edge-center-edge” techniques. A Friedman rank sum test for comparison of rank scores between methods for each reader resulted in p-values of 0.82, 0.82 and 1.00. Average ranking over all readers is shown in Fig. 1b. In fact, the difference in image quality of the dynamic scans seemed more strongly correlated with the order of the injection, rather than the image method used (Fig. 1c). Fig. 2 presents steady-state axial images of a representative volunteer. The ECG-gated ECE images were favored by all readers (p-values 0.002, 0.045 and 0.0008) in forced-ranking of image quality. However, these differences were extremely subtle and occurred mostly within the heart and aortic root. It was not possible for the readers to differentiate the images on the basis of image quality within the lungs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

سنجش مقادیر تروپونین ? قلبی در بیماران مبتلا به آمبولی حاد ریه و ارتباط آن با اختلال عملکرد بطن راست

Background and purpose: Right ventricular dysfunction is common in major pulmonary embolisms. The purpose of this study was to evaluate the prevalence and diagnostic utility of cardiac troponin I and also to identify patients with RV dysfunction in pulmonary embolism. Materials and methods: This study was conducted on 42 patients with pulmonary embolism in Ekbatan Hospital, in Hamedan city. ...

متن کامل

Improved cardiac motion self-gating

Background Cardiac motion self-gating is a technique where MRI signal is used to derive motion triggers instead of ECG, which might be problematic in high B0 field or cases where ECG is not accessible (e.g. fetal cardiac imaging). However, the performance of existing cardiac self-gating approaches have not yet enabled clinical utility. We propose and evaluate here a novel cardiac self-gating st...

متن کامل

Early post operative mortality of Total Correction of Tetralogy of Fallot

Introduction: Since 1954, after the first surgical repair of tetralogy of Fallot (TOF), several innovations have occurred in cardiac surgery, especially in children. One stage complete repair of TOF is currently possible even in infancy; however, complications such as hypoxemia, arrhythmia, cardiac dysfunction, sudden death, and valvular disorders may happen. In this study, we evaluated the res...

متن کامل

Functional MRI of the Lung

Imaging of the pulmonary parenchyma represents a unique challenge for MRI. Limited signal is caused by low proton density, susceptibility artefacts, and physiological motion (cardiac pulsation, respiration). Improvements in MRI techniques have extended the potential for investigations of pulmonary parenchymal disease with the evaluation of lung perfusion. More recently inhalation of non proton-...

متن کامل

A rare combination of cardiopulmonary anomalies demonstrated on ventilation-perfusion scan.

In this case report we describe an unusual appearance seen on a ventilation-perfusion (V/Q) scan in a woman with pulmonary hypertension. Although the pulmonary hypertension was not caused by pulmonary emboli, the V/Q scan suggested several cardiac anomalies which may lead to pulmonary hypertension. Most of the cardiac anomalies, including right-sided aortic arch and right-to-left shunt, can be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010