Effect of Corneal Incision Enlargement on Surgically Induced Astigmatism in Biaxial Microincision Cataract Surgery

نویسندگان

  • Mehmet Tetikoğlu
  • Celal Yeter
  • Fırat Helvacıoğlu
  • Serdar Aktaş
  • Hacı Murat Sağdık
  • Fatih Özcura
چکیده

OBJECTIVES To evaluate surgically induced astigmatism (SIA) in biaxial microincision cataract surgery with enlargement of one corneal incision during intraocular lens implantation (IOL). MATERIALS AND METHODS Data from 683 eyes with cataract that underwent biaxial microincision cataract surgery and IOL were retrospectively analyzed. The operated eyes were divided into 4 groups defined by final corneal incision length after IOL implantation. There were 83 eyes with 1.6 mm corneal incisions (group 1) and 200 eyes in each of the 2, 2.4, and 2.8 mm corneal incision groups (groups 2, 3 and 4, respectively). SIA was assessed using preoperative and postoperative keratometric values at one month. RESULTS The mean magnitude of SIA was 0.83±0.4 D in group 1, 0.93±0.5 D in group 2, 1.03±0.6 D in group 3 and 1.04±0.7 D in group 4. The SIA showed statistically significant differences between the four groups (p=0.05). Pairwise group comparisons revealed significant differences between groups 1 and 3 and groups 1 and 4 (p=0.005). CONCLUSION Biaxial microincision cataract surgery with an incision size of 1.6 mm resulted in the least SIA. Enlargement of the corneal incision beyond 2.0 mm during IOL implantation led to significant increases in SIA. We believe that with the development and dissemination of IOLs which can be inserted through small corneal incisions, biaxial microincision cataract surgery will be the best choice to prevent SIA and increase visual acuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery.

AIM To compare the optical outcomes of biaxial microincision cataract surgery (B-MICS) versus coaxial small-incision cataract surgery (C-SICS). METHODS Thirty patients (sixty eyes) with bilateral age-related cataract underwent B-MICS through a 1.7 mm clear corneal incision (CCI) in one eye and C-SICS through a 2.8-mm CCI in the other eye. Every eye was implanted with a micro-incision aspheric...

متن کامل

Aspheric microincision intraocular lens implantation with biaxial microincision cataract surgery: efficacy and reliability.

PURPOSE To evaluate the efficacy and reliability of a microincision intraocular lens (IOL) and its use in biaxial microincision cataract surgery (MICS). SETTING Atatürk Training and Research Hospital, Ankara, Turkey. DESIGN Prospective clinical study. METHODS A microincision IOL (Akreos MI60) was implanted after cataract extraction by the biaxial MICS technique. Over a postoperative follo...

متن کامل

Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study.

PURPOSE To compare the effects of biaxial microincision cataract surgery (B-MICS) and microcoaxial cataract surgery (C-MICS) techniques on corneal optical quality. MATERIALS AND METHODS In this prospective study, 40 eyes underwent B-MICS and 40 eyes C-MICS. Corneal aberrations were derived from conversion of the corneal elevation profile into corneal wavefront data with 6.0  mm aperture diame...

متن کامل

Coaxial, microcoaxial, and biaxial microincision cataract surgery

METHODS: In this prospective randomized study, patients had standard coaxial (2.8 mm incisions), microcoaxial (2.2 mm incisions), or biaxial microincision (1.2 to 1.4 mm trapezoidal incisions) phacoemulsification. Intraoperative phaco parameters and total surgical time were measured and complications recorded. Postoperative visual acuity improvement, pachymetric differences, and surgically indu...

متن کامل

Comparison of Surgically-induced Astigmatism after Combined Phacoemulsification and 23-Gauge Vitrectomy: 2.2-mm vs. 2.75-mm Cataract Surgery

PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2016