Intracellular ionic concentration by calibration from fluorescence indicator emission spectra, its relationship to the K(d), F(min), F(max) formula, and use with Na-Green for presynaptic sodium.

نویسندگان

  • James L Winslow
  • Robin L Cooper
  • Harold L Atwood
چکیده

The emission spectra calibration curves for a fluorescence indicator and the F(min), F(max), and K(d) formula were shown to be related. Using the known calibrated fluorescence emitted by Sodium Green (Na-Green) and photo-multiplier-tube quantum efficiency, we calculated the detection signal over a range of sodium concentrations. The calculated calibration curves were compared for optical filters passing a narrow band, medium band or full spectrum. We found that a method based on the full emission spectrum was the most appropriate. Given a known resting concentration of intracellular sodium, calibrated readings can be converted to concentration values. This method is applicable to any fluorescence indicator when curves for emission spectra over a range of concentrations are available. We measured sodium concentration changes during trains of action potentials (APs) at a crayfish motor axon's presynaptic terminals injected with Na-Green. During low frequency AP trains, net sodium increases asymptotically with frequency. Average net Na-flux per AP decreases for increasing terminal size. The terminals of crayfish motor axon have surface area to volume ratio which is 7700 times larger than for squid. Thus, in comparison to squid, crayfish terminals exhibit a larger change in [Na(+)](i) during equivalent AP activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Fluorescence Behavior and Stability ‎of AgNPs Synthesized by Juglans Regia ‎Green Husk Aqueous Extract

   Particles with the size of 1-100 nm are known as nanoparticles (NPs). The widespread use of silver NPs (AgNPs) makes it familiar in different industries. They have unique properties as a result of their high surface to volume ratio, although aggregation of NPs interferes with their functions. This phenomenon has several side effects on the environment, the amount of which may depend on t...

متن کامل

A new method for Eosin preparation and examination of its absorption and emission spectra

Eosin is one of the original dyes of xanthenes derivatives. It is also one of the main derivatives of fluorescein and has brilliant fluorescence. Eosin disodium salt called "Eosin Y" is the most useful form of this compound. In common procedures, eosin is usually obtained by the action of bromine on fluorescein, which has not good yield and purity degree. In this research, it is prepared by the...

متن کامل

Posttetanic potentiation at the crayfish neuromuscular junction is dependent on both intracellular calcium and sodium ion accumulation.

The fluorescent indicator fura-2 was used to measure cytoplasmic calcium in presynaptic terminals in the crayfish Procambarus clarkii under conditions that raise intracellular sodium to examine whether sodium can elevate intracellular calcium concentration ([Ca2+]i) or prolong its efflux and thus influence the magnitude and duration of posttetanic potentiation (PTP). Sodium was elevated in pres...

متن کامل

Inner Filter Effect in the Fluorescence Emission Spectra of Room Temperature Ionic Liquids with-β-Carotene

Steady-state fluorescence spectroscopy is highly sensitive an analytical fluorescence detecting tool limited to diluted samples. The serious problem of quantitative analysis is dominant in the samples with optical density higher than 0.05 (10 mm cell) detected in the right angle cell geometry, because of the two kinds of inner filter effects IFEs (Lakowicz, 2006; Li & Hu, 2007; Kao et al., 1998...

متن کامل

ISOLATION AND CHARACTERIZATION OF SIX HIGHLY INTRINSIC FLUORESCENT METABOLITES IN ARMILLARIA MELLEA (VAHL. EX. FR.) KARST

Six fluorescent compounds were isolated and characterized in rhizomorph of A. mellea and were presented first as: F , F , F , MF , MF and MF . These compounds differed by Rf on chromatoplaque, max in UV spectra and ex, em and max in fluorescence spectra. Their GC-MS analysis indicated that F has a phenolic moiety and the other five are the benzenic derivatives. F compound was more f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 118 2  شماره 

صفحات  -

تاریخ انتشار 2002