Mechanical Preparation Showed Superior Shaping Ability than Manual Technique in Primary Molars - A Micro-Computed Tomography Study.

نویسندگان

  • Lídia Regina da Costa Hidalgo
  • Léa Assed Bezerra da Silva
  • Graziela Bianchi Leoni
  • Jardel Francisco Mazzi-Chaves
  • Emily Eduardo da Silva Carvalho
  • Alberto Consolaro
  • Manoel Damião Sousa-Neto
چکیده

The aim of the study was to evaluate canal preparation in primary molars with hand files, ProTaper Next and Self-Adjusting File (SAF) by 2D and 3D micro-computed tomography (micro-CT) analysis. Canals of 24 primary molars were prepared with hand files (HF), ProTaper Next (PTN) and SAF (n=8/group). The teeth were scanned before and after root canal preparation and the pre- and postoperative micro-CT images were reconstructed. Changes in 2D (area, perimeter, roundness, minor and major diameter) and 3D [volume, surface area, structure model index (SMI)] morphological parameters, as well as canal transportation and lateral perforations were evaluated (Kruskal-Wallis and ANOVA; a=0.05). SAF presented smaller changes in minor diameter, volume and surface area compared with HF and PTN (p<0.05). PTN presented more circular canals after preparation. 3D analysis revealed greater transportation in HF. PTN and SAF presented more centered canal preparation, especially in curved areas. SAF and HF presented, respectively, the lowest (0.05±0.02 and 0.07±0.04) and highest (0.14±0.11 and 0.29±0.17) apical transportation. There were fewer lateral perforations in SAF (4.2%) and PTN (7.7%) than in HF (47.8%) (p<0.05). In primary molars, mechanical preparation showed better shaping ability than hand files, promoting more centered preparations and lower occurrence of lateral perforations and canal transportation. CLINICAL RELEVANCE Manual instrumentation is still reported as the main choice in the primary teeth preparation; however, studies have shown limitations in its use. The morphological characteristics of primary teeth and the limited knowledge of shaping procedures in these teeth using mechanical preparation become a challenge for clinical practice and might impair the predictability of endodontic treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography

Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...

متن کامل

Effects of preparation techniques on root canal shaping assessed by micro-computed tomography

BACKGROUND Root canal shaping without any procedural error is of the utmost preference. Therefore, the purpose of this study was to use micro-computed tomography to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and were divided into 2 groups of 30. Be...

متن کامل

Comparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study

BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...

متن کامل

Comparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography

Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...

متن کامل

Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

BACKGROUND Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth eac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2017