Transcatheter paravalvular leak closure and hemolysis – a prospective registry
نویسندگان
چکیده
INTRODUCTION Paravalvular leak (PVL) related to a surgical prosthetic valve may be associated with clinically significant hemolysis. The influence of transcatheter PVL closure (TPVLC) on hemolysis remains uncertain. MATERIAL AND METHODS The prospective registry included patients undergoing TPVLC due to PVL-related heart failure and/or hemolysis. Procedural data, laboratory markers of hemolysis and heart failure status were recorded at baseline, discharge and at 1- and 6-month follow-up. RESULTS Of 116 patients from all those qualified for TPVLC, 79 fulfilled the inclusion/exclusion criteria. Hemolysis was significantly more frequent in patients with mitral location of PVL and with calcifications in its channel. After TPVLC prompt reduction of lactate dehydrogenase activity (617.0 (342.0-899.0) vs. 397 (310.0-480.5) IU/l, p < 0.05) and gradual resolution of anemia (hemoglobin (HGB) 11.7 (10.4-13.8) vs. 13.4 (12.9-13.8) g%, p < 0.05) over 6 months were noted. Effective closure of PVL (> 90% reduction of PVL cross-sectional area) resulted in a more prominent increase of red blood cell count and HGB than in patients with residual regurgitation. The TPVLC-related exacerbation of hemolysis was recorded in 14 patients. Its risk was aggravated by presence of significant hemolysis at baseline or residual flow either by a partially uncovered channel or across the occluder. Reduction of hemolysis after successful TPVLC was sustained in 6-month follow-up. CONCLUSIONS Risk factors for PVL-related hemolysis were the presence of calcifications in the defect and mitral location of PVL. The TPVLC effectively reduced hemolysis if at least 90% reduction of PVL cross sectional area was achieved. The effect was sustained in 6-month follow-up. Incomplete closure of PVL may increase the magnitude of hemolysis after TPVLC, but it occurred rarely.
منابع مشابه
Clinical manifestations of heart failure abate with transcatheter aortic paravalvular leak closure using Amplatzer vascular plug II and III devices.
OBJECTIVES To evaluate the transcatheter paravalvular leak closure (TPVLC) aptitude to reduce manifestations of heart failure caused by aortic paravalvular leak (PVL). BACKGROUND TPVLC is a valuable alternative to reoperation. While technical feasibility of the method is well established, data on long-term clinical outcome are less abundant. METHODS We launched a prospective registry of pat...
متن کاملTranscatheter closure of paravalvular leaks using a paravalvular leak device – a prospective Polish registry
INTRODUCTION Transcatheter paravalvular leak closure (TPVLC) has become an established treatment option but is mostly performed with off-label use of different non-dedicated occluders. The first one specifically designed for TPVLC is the paravalvular leak device (PLD - Occlutech). AIM We present initial short-term results of a prospective registry intended to assess the safety and efficacy of...
متن کاملPercutaneous Closure of an Aortic Prosthetic Paravalvular Leak with Device in a Patient Presenting with Heart Failure
Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Perivalvular prosthetic regurgitation causes significant morbidity and is associated with high perioperative mortality if open surgical repair is required. PVLs manifest with symptoms of congestive heart failure, hemolysis, or in most cases, the combination of both. In recent years, the development of ...
متن کاملTranscatheter aortic paravalvular leak closure using 3 Amplatzer Vascular Plug III devices in a child
Paravalvular leak (PVL) is usually related to disruption of prosthetic valve sewing ring sutures. Many previous reports have described transcatheter paravalvular leak closure in adult patients [1–4], but those describing such a procedure in children are scarce. A 16-year-old boy underwent an aortic valve replacement (AVR) with a stented bioprosthesis Hancock 23 mm due to combined aortic stenosi...
متن کاملTransapical closure of mitral prosthetic paravalvular leak.
Clinically significant mitral prosthetic paravalvular leaks may occur in up to 5% of patients following surgical mitral valve replacement. Successful closure may offer relief from symptoms of heart failure and hemolysis, but surgical closure is associated with increased morbidity and mortality. Alternative transcatheter closure techniques are being developed. We present a patient who was succes...
متن کامل