Surfactant and Pulmonary Blood Flow

نویسندگان

  • Alan Jobe
  • Machiko Ikegami
چکیده

Prematurely delivered lambs were treated with radiolabeled natural surfactant by either tracheal instillation at birth and before the onset of mechanical ventilation, or after 23±1 (±SE) min of mechanical ventilation. Right ventricular blood flow distributions, left ventricular outputs, and left-to-right ductal shunts were measured with radiolabeled microspheres. After sacrifice, the lungs of lambs receiving surfactant at birth inflated uniformly with constant distending pressure while the lungs of lambs treated after a period of ventilation had aerated, partially aerated, and atelectatic areas. All lungs were divided into pieces which were weighed and catalogued as to location. The amount of radiolabeled surfactant and microsphere-associated radioactivity in each piece oflung was quantified. Surfactant was relatively homogenously distributed to pieces of lung from lambs that were treated with surfactant at birth; 48% of lung pieces received amounts of surfactant within ±25% of the mean value. Surfactant was preferentially recovered from the aerated pieces of lungs of lambs treated after a period of mechanical ventilation, and the distribution of surfactant to these lungs was very nonhomogeneous. Right ventricular blood flow distributions to the lungs were quite homogeneous in both groups of lambs. However, in 8 of 12 lambs, pulmonary blood flow was preferentially directed away from those pieces of lung that received relatively large amounts of surfactant and toward pieces oflung that received less surfactant. This acute redirection of pulmonary blood flow distribution may result from Address all correspondence to Dr. Jobe. Received for publication 8 February 1983 and in revised form 4 October 1983. the local changes in compliances within the lung following surfactant instillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute effects of instillation of surfactant in severe respiratory distress syndrome.

Doppler ultrasound measurements of pulmonary blood flow in 20 babies with severe respiratory distress syndrome treated in a randomised controlled trial of surfactant replacement showed that the immediate improvement of oxygenation was not associated with a significant increase in pulmonary blood flow. Reduction in ventilator settings and increases in the extent of chest wall movements measured ...

متن کامل

Pulmonary haemodynamics after surfactant replacement in severe neonatal respiratory distress syndrome.

Aortopulmonary pressure difference and pulmonary blood flow velocity were studied during the first 48 hours of life in 12 premature neonates with severe respiratory distress syndrome (RDS), treated by natural surfactant, and in 25 premature neonates with mild RDS. A non-invasive Doppler ultrasound method was used to estimate aortopulmonary pressure difference and pulmonary blood flow velocity f...

متن کامل

Cerebral blood flow velocity changes after rapid administration of surfactant

A computer linked Doppler system was used to make continuous measurements of cerebral blood flow velocity (CBFV) from the middle cerebral artery, mean arterial blood pressure (MAP) from the umbilical artery, and heart rate before, during, and for 20 minutes after the endotracheal administration of 200 mg/kg of porcine surfactant in 10 preterm infants with respiratory distress syndrome. Within t...

متن کامل

Cerebral blood flow velocity changes after rapid administration of surfactant.

A computer linked Doppler system was used to make continuous measurements of cerebral blood flow velocity (CBFV) from the middle cerebral artery, mean arterial blood pressure (MAP) from the umbilical artery, and heart rate before, during, and for 20 minutes after the endotracheal administration of 200 mg/kg of porcine surfactant in 10 preterm infants with respiratory distress syndrome. Within t...

متن کامل

The adsorption of biomolecules to multi-walled carbon nanotubes is influenced by both pulmonary surfactant lipids and surface chemistry

BACKGROUND During production and processing of multi-walled carbon nanotubes (MWCNTs), they may be inhaled and may enter the pulmonary circulation. It is essential that interactions with involved body fluids like the pulmonary surfactant, the blood and others are investigated, particularly as these interactions could lead to coating of the tubes and may affect their chemical and physical charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013