Limitations to quality control materials for CO-oximeters.

نویسنده

  • A Van Driel
چکیده

13 Ball EG, Strittmalter CF, Cioper 0 . The reaction of carbon monoxide. J Biol Chem 1951; 193:635-47 14 Chance B, Erecinska, Wagner M. Mitochondria1 responses to CO toxicity. Ann NY Acad Sci 1970; 174:193-204 15 Roughton FJW, Darling RC. The effect of carbon monoxide on the oxyhemoglobin dissociation curve. Am J Physiol 1944; 141: 17-31 16 Mackison FW, Stricoff RS, Patridge LJ, eds. Occupational health guidelines for chemical hazards. Bethesda: NIOSH/OSHA, 1978, publication 81-123 17 Kindwall El? Carbon monoxide. In: Zenz C, ed. Occupational medicine: principals and practical applications. Chicago: Yearbook Publishers, 1975; 605-12 18 Kurt TL. Chemical asphyxiants. In: Rom WN, ed. Environmental and occupational medicine. Boston: Little Brown, 1983; 290-92

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudomethemoglobinemia: a case report and review of sulfhemoglobinemia.

OBJECTIVES To see if methemoglobin could potentially be misdiagnosed and the limitation of present cooximeters. PATIENT A 17-year-old girl who overingested a combination of cimetidine, acetaminophen, ibuprofen, and naproxen in a suicide attempt. METHOD Use of pulse co-oximeters to aid in the diagnosis of suspected sulfhemoglobinemia. RESULTS Diagnosis of sulfhemoglobinemia achieved with f...

متن کامل

Measurement of carboxyhemoglobin and total hemoglobin by five specialized spectrophotometers (CO-oximeters) in comparison with reference methods.

We measured total hemoglobin (CtHb) and carboxyhemoglobin (COHb) in 100 patients' blood samples by using five specialized spectrophotometers (CO-oximeters)--IL 482 CO-Oximeter, Corning 2500 CO-oximeter, Radiometer OSM 3 Hemoximeter, Corning 270 CO-oximeter, and the AVL 912 CO-Oxylite--and compared the results with those obtained with the manual cyanmethemoglobin method and a gas-chromatographic...

متن کامل

CO-oximetry interference by perflubron emulsion: comparison of hemolyzing and nonhemolyzing instruments.

Perflubron emulsion is expected to be in clinical use soon as a non-hemoglobin blood substitute. A preliminary report indicates that this new oxygen-carrying fluorocarbon interferes with the measurements of CO-oximeters. Therefore, we have quantified the interference that perflubron causes in the measurements of eight widely used oximeters and CO-oximeters. The AVL Omni 6, CC270, IL482, IL682, ...

متن کامل

Audit of oxygen therapy in acute general medical wards following an educational programme.

INTRODUCTION Previous studies have shown that the administration of supplementary oxygen (O2) in hospitalised patients outside the intensive care units (ICU) was usually empirical, inappropriate and not in compliance with physiological guidelines. It has been suggested that routine use of portable pulse oximeters in general wards plus in-service education of doctors and nurses may ameliorate th...

متن کامل

Pulse oximetry: theory and applications for noninvasive monitoring.

Noninvasive measurement of arterial oxygen saturation (SaO2) by pulse oximetry is widely acknowledged to be one of the most important technological advances in monitoring clinical patients. Pulse oximeters compute SaO2 by measuring differences in the visible and near infrared absorbances of fully oxygenated and deoxygenated arterial blood. Unlike clinical blood gas analyzers, which require a sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 87 3  شماره 

صفحات  -

تاریخ انتشار 1985