Keraring Intrastromal Segment Depth Measured by Spectral-Domain Optical Coherence Tomography in Eyes with Keratoconus

نویسندگان

  • Ugo de Sanctis
  • Carlo Lavia
  • Marco Nassisi
  • Savino D'Amelio
چکیده

Purpose. To evaluate agreement between measured and intended distance of Keraring (Mediphacos, Belo Horizonte, Brazil) intracorneal ring segments from the anterior and posterior corneal surfaces. Methods. Twenty-six Keraring ICRS implanted in 24 keratoconic eyes were examined. The distance from the Keraring apex to the anterior corneal surface and the distance from the inner and the outer corners to the posterior corneal surface were measured 3 months postoperatively using spectral-domain optical coherence tomography. Agreement between measured distance and intended distance was assessed by calculating the absolute differences and 95% limits of agreement (95% LoA). Results. The mean absolute difference was significantly lower (p < 0.001) for the measurements taken at the inner corner (23.54 ± 15.90 μm) than that for those taken at the apex (108.92 ± 62.72 μm) and the outer corner (108.35 ± 56.99 μm). The measurements taken at the inner corner were within ±25 and ±50 μm of the intended distance in 15/26 (57.7%) and 24/26 (92.3%) cases, respectively, and showed the narrowest 95% LoA with the intended distance (-57.61 to 55.15 μm). Conclusions. The distance of the inner corner from the posterior corneal surface showed the best agreement with the intended distance. This measurement is suitable for determining whether the actual Keraring depth matches the intended depth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictability of Tunnel Depth for Intrastromal Corneal Ring Segments Implantation Between Manual and Femtosecond Laser Techniques.

PURPOSE To compare the predictability of intrastromal tunnel depth creation for intrastromal corneal ring segments (ICRS) implantation between manual dissection and femtosecond laser using a high-resolution anterior segment optical coherence tomography (AS-OCT). METHODS This multicenter study included patients with keratoconus who had Ferrara-type ICRS implantation at Hospital de Braga using ...

متن کامل

Outcome of Keraring Intrastromal Corneal Ring Segment Implantation for the Management of Keratoconus

Objective: To report the outcome of Keraring intrastromal corneal ring segment implantation using mechanical tunnel creation method for the management of keratoconus. Patients and Methods: This study was conducted during the period from July 2009 to November 2011 at Dhahran Eye Specialist Hospital, Dhahran, Saudi Arabia. It included 38 patients (40 eyes) with keratoconus who underwent Keraring ...

متن کامل

Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

PURPOSE To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus. DESIGN Prospective consecutive interventional study. PARTICIPANTS Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, an...

متن کامل

Keratoconus treatment using femtosecond-assisted intrastromal corneal graft (FAISCG) surgery: a case series

We describe an intrastromal corneal graft technique that uses femtosecond laser to create a desirable corneal lenticule with precise diameter, depth, and shape as well as an intra-stromal pocket in keratoconus patients. The technique seems to be a feasible and safe treatment option to treat keratoconic eyes with reference to the irregularity and instability of cornea. The technique can be perfo...

متن کامل

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017