Left ventricular assist device-related systolic aortic regurgitation.

نویسندگان

  • Jerson Martina
  • Nicolaas de Jonge
  • Eveline Sukkel
  • Jaap Lahpor
چکیده

A 39-year-old woman underwent transesophageal echocardiography during heart transplantation after 2.5 years of support with a continuous-flow left ventricular assist device (cf-LVAD). The patient was admitted to the hospital when a donor heart became available, and did not present with any symptoms or signs of heart failure on cf-LVAD support. Color-flow imaging demonstrated pronounced systolic aortic regurgitation (AR) while the LVAD was providing full support. The development of this unusual LVAD-related systolic AR may involve dynamic changes in resistance to flow of the aortic valve of an unknown mechanism. In most cases involving a combination of cf-LVAD support and aortic valve incompetence, AR would manifest as a mild-to-moderate diastolic or continuous valve regurgitation.1 Surprisingly, the patient demonstrated pronounced systolic AR (Figure 1and Movie in the online-only Data Supplement) on support with a Heartmate II LVAD (Thoratec Corp, Pleasanton, CA). At that time, the electrocardiogram showed low voltage and widespread T-top abnormalities, but was not changed in comparison with previous registrations (Figure 2). Furthermore, the chest x-ray showed no signs of heart dilation and decompensation while on LVAD support (Figure 3). Mean arterial pressures were nonpulsatile (mean, 70 mm Hg) at a pump speed setting of 9400 rpm at the time of echocardiography assessment. It is suggested that the development of systolic AR might be related to dynamic changes in the resistance to flow of the aortic valve along with consistent aortic valve closure. The mechanism allowing systolic AR to manifest has yet to be explained. Hence, when the aortic valve would be consistently closed and incompetent at the same time, aortic AR might occur throughout the entire cardiac cycle. It is possible that decrease in resistance to flow of the aortic valve during systole rather than diastole may have caused explicitly systolic AR in this patient to manifest. Accordingly, dynamic movements of the aortic valve annulus and valve leaflets during LVAD support may explain this phenomenon. Similarly, local pressure disturbances around the valve leaflets induced by turbulent flow patterns of the cf-LVAD may be a potential cause as well. Even so, we do not know whether this phenomenon is caused by purely physiological effects of the cf-LVAD, or it involves primarily anatomic factors. Perhaps in association with good-functioning cf-LVAD at the time of heart transplantation, no evidence was found that indicates that the systolic AR carried any hemodynamic significance in this patient. Thus, more detailed assessment strategies are Figure 1. (A) Color Doppler mapping of the parasternal long axis with transesophageal echocardiography of a patient supported by a continuous-flow LVAD during systole. This image shows systolic AR while the aortic valve is closed (arrow) along with coexistence of mitral AR (arrowhead). (B) Through the diastolic phase no AR is observed. This confirms the explicit systolic nature of the AR in this patient. LVAD indicates left ventricular assist device; AR, aortic regurgitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Images in Cardiovascular Medicine Left Ventricular Assist Device-Related Systolic Aortic Regurgitation

A 39-year-old woman underwent transesophageal echocardiography during heart transplantation after 2.5 years of support with a continuous-flow left ventricular assist device (cf-LVAD). The patient was admitted to the hospital when a donor heart became available, and did not present with any symptoms or signs of heart failure on cf-LVAD support. Color-flow imaging demonstrated pronounced systolic...

متن کامل

Transesophageal echocardiographic guidance of transcatheter closure of the aortic valve in a patient with left ventricular assist device-related severe aortic regurgitation

A 68 year-old man with a severe ischemic cardiomyopathy underwent left ventricular assist device (LVAD) implantation (Heart Mate II device) for destination therapy. He presented 49 months following LVAD implant with worsening heart failure symptoms and new severe aortic regurgitation. Given high risk for both surgical and transcatheter aortic valve replacement, he was admitted for transcatheter...

متن کامل

Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually im...

متن کامل

Aortic regurgitation after left ventricular assist device placement.

A 1 60-YEAR-OLD man with a history of recent heart failure caused by both primitive and ischemic dilated cardiomypathy underwent the successful implantation of a left ventriclar assist device (Novacor LVAS; WorldHeart, Ottawa, ON, anada) under cardiopulmonary bypass. Intraoperative transsophageal echocardiography (TEE) performed immediately fter implantation showed the correct placement of both...

متن کامل

Evaluation of relationship between myocardial contractile state and left ventricular function in patients with aortic regurgitation.

We studied the relationship between myocardial contractile state and left ventricular functional response to exercise in 14 asymptomatic patients with isolated moderate-to-severe aortic regurgitation and six control subjects. The slope of the systolic blood pressure-left ventricular end-systolic volume (pressure-volume) relationship determined by radionuclide ventriculography during angiotensin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2011