Translucency & Radiopacity of Five Resin Composites

نویسندگان

  • James M. Thompson
  • Sue Thompson
چکیده

Objective: Determine the translucency and radiopacity of five commercially availablecomposites: Aelite LS(AE), Filtek LS(FS), GC Kalore(KA), Empress DirectEnamel(EE), Empress Direct Dentin(ED)Experimental Methods: Experiment conducted according to ISO guideline 4049.Five composites(n=50), shade A2, were packed into an aluminum mold(10-mm diameter,1-mm thick) and light cured for 80 seconds(40 sec each side). The color of eachspecimen was measured according to the CIELAB color scale relative to the standardilluminant D65 against a white background and a black background using a reflectionspectrophotometer with a 8mm (MAV) diameter target mask. Using color data,translucency parameter and contrast ratio were calculated for each sample. Forradiopacity, five specimens(1 for each composite) were placed in random order with analuminum step wedge(20-mm x 50-mm, 10 0.5-mm steps) on an occlusal film andexposed at 70kV, 7mV, 0.339sec from a target-film distance of 360-mm. Afterimmediately being processed(10 radiographs), the radiographic optical densities of thespecimens and aluminum step wedge were read with a photographic transmissiondensitometer(aperture 1-mm). Aluminum equivalent was calculated using regressionanalysis(mean optical density vs. mean thickness aluminum step wedge). A visualanalysis by two independent examiners was also done and compared to the ISO 4049radiographic method. One-way ANOVA(p<0.05) and Tukey multiple comparisontests(p<0.05) were used for statistical analysis.Results: EE was the most translucent (22.089) and had the lowest contrast ratio(0.783)while AE was the least translucenct(11.808) and had the highest contrast ratio(0.908).For translucency all five composites were significantly different. For contrast ratio,except KA and FS, which were similar, all composites were significantly different. Therewas a very strong inverse correlation between translucency parameter and contrast ratio(-0.944). According to ISO guidelines 4049, a composite material is deemed radiopaque ifthe aluminum equivalent value of the material is greater than 1 mm. All five compositesmet this criteria with ED having the highest radiopacity(3.609 AlEq) and AE having thelowest radiopacity(1.263AlEq). All of the composites were significantly different exceptAE and FS, which were similar. Visually, ED was deemed the most visually radiopaqueby examiners and was significantly different than the other composites while EE/KA andFS/AE were not significantly different. FS and AE were least radiopaque visually. Therewas a strong correlation(0.938) between Al Radio Equiv and Visual Al Equiv whencomparing the materials as a group. There was much variation when correlating betweeneach material. There was a very weak to no correlation between radiopacity Al Equivand translucency(0.084) and contrast ratio(0.053).Conclusions: EE was the most translucent material. AE can be considered a veryopaque material but was the second most radiolucent material. ED had the highestradiopacity of the five composites but all five composites met ISO 4049 guidelines forradiopacity. Radiopacity and translucency were not correlated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiopacity measurements of direct and indirect resin composites at different thicknesses using digital image analysis.

Radiopacity is an important property of composite materials for clinical diagnosis. For seven direct composites (Aelite LS Posterior, Aelite All-Purpose Body, Quadrant Universal LC, Clearfil Majesty Posterior, Clearfil Majesty Esthetic, Filtek Ultimate Dentin, IPS Empress Direct Dentin) and six indirect composites (Ceromega, Epricord, Estenia C&B, Tescera, Signum Ceramis, Solidex), diskshaped s...

متن کامل

Radiopacity evaluation of contemporary resin composites by digitization of images

OBJECTIVE The aim of this study was to evaluate the radiopacity of different composite resins and compare the values to those of human enamel and dentine. MATERIALS AND METHODS Five specimens of each material with thicknesses of 2 mm were prepared and radiographed alongside aluminum step wedge and human enamel and dentin. Three occlusal radiographs for each material were taken and digitized u...

متن کامل

Radiopacity of Methacrylate and Silorane Composite Resins Using a Digital Radiographic System

The aim of this study was to evaluate the radiopacity of silorane and methacrylate resin composites, comparing them to the enamel, dentin, and aluminum penetrometer using a digital image. From six resin composites (Filtek™ P90, Filtek Z350, Filtek Z350 XT flow, Tetric Ceram, TPH Spectrum, and SureFil SDR flow) cylindrical disks (5 × 1 mm) were made and radiographed by a digital method, together...

متن کامل

Translucency and characteristics of newly developed polymer-based dental tooth coating material.

The purpose of this study was to evaluate the translucency and color change of simulated heavily discolored teeth using polymer-based dental tooth coating materials and flowable resin composites. Five shades of coating material and two shades of flowable resin composite were used. Colorimetric values of the materials in different shades were determined using the L*a*b* system of the Commission ...

متن کامل

Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites

OBJECTIVES This study evaluated the effects of the resin thickness on the microhardness and optical properties of bulk-fill resin composites. METHODS Four bulk-fill (Venus Bulk Fill, Heraeus Kulzer; SDR, Dentsply Caulk; Tetric N-Ceram Bulk Fill, Ivoclar vivadent; SonicFill, Kerr) and two regular resin composites (Charisma flow, Heraeus Kulzer; Tetric N-Ceram, Ivoclar vivadent) were used. Sixt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012