Hydrodynamic loading and viscous damping of patterned perforations on microfabricated resonant structures
نویسندگان
چکیده
Related Articles Nanoscale temperature sensing using the Seebeck effect J. Appl. Phys. 111, 084306 (2012) Vimentin networks at tunable ion-concentration in microfluidic drops Biomicrofluidics 6, 022009 (2012) Note: Adhesive stamp electrodes using spider silk masks for electronic transport measurements of supra-micron sized samples Rev. Sci. Instrum. 83, 046106 (2012) Covalently immobilized biomolecule gradient on hydrogel surface using a gradient generating microfluidic device for a quantitative mesenchymal stem cell study Biomicrofluidics 6, 024111 (2012) High-performance microfluidic rectifier based on sudden expansion channel with embedded block structure Biomicrofluidics 6, 024108 (2012)
منابع مشابه
Foundation damping and the dynamics of offshore wind turbine monopiles
The contribution of foundation damping to offshore wind turbines (OWTs) is not well known, though researchers have back-calculated foundation damping from “rotor-stop” tests after estimating aerodynamic, hydrodynamic, and structural damping with numerical models. Because design guidelines do not currently recommend methods for determining foundation damping, it is typically neglected. This pape...
متن کاملSoil-Structure Modeling and Design Considerations for Offshore Wind Turbine Monopile Foundations
The contribution of foundation damping to offshore wind turbines (OWTs) is not well known, though researchers have back-calculated foundation damping from “rotor-stop” tests after estimating aerodynamic, hydrodynamic, and structural damping with numerical models. Because design guidelines do not currently recommend methods for determining foundation damping, it is typically neglected. This pape...
متن کاملEquivalent Damping Ratios of Structures with Supplemental Viscous Dampers
The current design formulas such as those provided by FEMA273/274 for building structures with supplemental viscous dampers were derived based on the shear building assumption. However, for medium-rise to high-rise buildings that deform in a combined form of shear and bending when subjected to seismic loading, the design using existing formulas may result into an actual damping ratio much lower...
متن کاملEffects of Degree of Consolidation and Anisotropic Consolidation Stresses on Shear Modulus and Damping Ratio of Cohesive Soils at Low Strain
During consolidation process of saturated cohesive soil the soil stiffness increases. Increase of the effective stress due to dissipation of excess pore pressure causes additional stiffness of soil mass. This phenomenon has a very important effect on the behavior of saturated cohesive soils during dynamic loading. In the current investigation the changes in maximum shear modulus. Gmax and dampi...
متن کاملVISCOUS DAMPER PLACEMENT OPTIMIZATION IN CONCRETE STRUCTURES USING COLLIDING BODIES ALGORITHM AND STORY DAMAGE INDEX
Dampers can reduce structural response under dynamic loads. Since dampers are costly, the design of structures equipped with dampers should make their application economically justifiable. Among the effective cost reduction factors is optimal damper placement. Hence, this study intended to find the optimal viscous damper placement using efficient optimization methods. Taking into account the no...
متن کامل