The effects of time and light exposure on contact and pressure measurements using Fuji prescale film.

نویسندگان

  • R Patterson
  • D Pogue
  • S Viegas
چکیده

The search for methods to demonstrate and accurately measure contact area and pressure within human joints has been and remains an active one. Presenssor is a measuring system developed by Fuji Photo Film Co., Ltd. and used in medical applications. The color intensity fades with time and exposure to light. These changes have not been well documented despite the increasing use of Fuji film in biomedical research. These changes in color intensity provide a source of error in the calculated measurements. The known variability of the color density of film exposed to light and air can be measured and predicted. Methods to control and improve the accuracy and reliability of study data are suggested. Film was exposed to three different amounts of pressure and placed into one of four subgroups: exposed to light and taped or not taped, and stored in the dark and taped or not taped. Fading of the color density was seen after only a few hours of exposure to light when the film was left untaped. When the film was taped, a slight darkening was seen. For the best accuracy and reliability, the film should be digitized or analyzed within eight hours of exposure to pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterilization of Fuji pressure-sensitive film.

Fuji Prescale film is a pressure-sensitive medium which produces a characteristic pink stain on the application of pressure. Up to a saturation level, increases in pressure will produce a denser stain, thereby providing a method of determining pressures within the interface between two articulating surfaces. The relationship between the magnitude of applied pressure and the optical density of t...

متن کامل

Soft-tissue balancing with pressure distribution during total knee arthroplasty.

We measured the pressure distribution across the tibiofemoral and patellofemoral joints during total knee arthroplasty (TKA) using Fuji pressure-sensitive film (Prescale) in 51 patients (63 joints) comparing the results with those in 21 patients in whom Prescale was not used. We classified the stress-distribution patterns in the tibiofemoral joints into four types: normal, varus-valgus instabil...

متن کامل

Inaccuracies in measurement of contact pressure due to the measuring grid of a foil sensor

The measurement of contact stresses between elastic bodies is of great importance in a wide range of fields. Many methods are based on a sensor sheet which is placed between the bodies in contact. Depending on the application, the accuracy of measuring results can be considerably affected by the finite thickness and structure of the inserted sensor. This study deals with the imprecision of the ...

متن کامل

[Clinical evaluation of measuring system of occlusal force].

An occlusal diagnostic system was evaluated for clinical applications. This system consists of pressure sensitive sheets (DENTAL PRESCALE, Fuji Photo Film Co.) and analyzing computer (OCCLUZER FPD703, Fuji Photo Film Co.). The clinical efficiency of this system was evaluated in aged dentates, aged complete denture wearers and an aged patient suffered from periodontitis. The results were as foll...

متن کامل

An Experimental Investigation of Water Effects on Asphaltene Surface Behavior through Interfacial Tension Measurements

As a physiochemical property, asphaltenes are known to be one the most surface active compounds in crude oil. Due to such property, their behavior is most probably influenced by fluid-fluid interactions at the contact surface (interface). Potentially and naturally, in most cases, water is in contact with crude oil and is co-produced with it as well. Considering that asphaltene molecules are pol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Iowa orthopaedic journal

دوره 17  شماره 

صفحات  -

تاریخ انتشار 1997